E-MNG MANAGEMENT SOFTWARE RELEASE NOTES Last Update 2020/12/02 This listing provides the version number of the NTI E-MNG (FORMERLY E-MS-SEMS) Enterprise Environment Monitoring System Management Software files, the date of the release, and a summary of the changes in that release. 3.6 2020/12/02 Bug Fix: Improves the Pop-Up alert performance Bug Fix: Corrects a problem with the pop-up alert sound not working properly. Bug Fix: Corrects a problem with the user configuration not working properly. Bug Fix: Corrects a problem with the E-1W & E-MICRO date/time settings for time format (AM/PM or 24 Hour). 3.5 2020/10/21 Feature Add: Adds support for custom audio alerts. Feature Add: Adds support for the E-1W sensor re-positioning feature(E-1W version 3.5 or newer software). Feature Add: Adds support for all sensors up to E-xD version 2.61 Feature Add: Adds support for E-Mail Test Feature Add: Adds support for Local Time settings Feature Add: Adds support for E-MICRO Alerts and Smart Alerts in the Summary Table. Feature Add: Adds Circular gauge display. Bug Fix: Corrects a problem with summary pages not showing sensors that have gone into alert, not saving the value in the alert log. Bug Fix: Corrects a problem with sensor names reverting to default after thresholds have been changed via the E-MNG software. Bug Fix: Corrects a Display problem where display windows are lost on re-start if the display window was partially positioned outside of the display area. Bug Fix: Corrects a problem with graph view periods not restoring properly on a client program re-start. 3.4 2019/07/29 Feature Add: Adds the ability to Cycle Sensor Power for Digital Inputs from the Client program. -Cycles the E-16D Digital Input 12V power or the E-5D / E-2D Aux 12V power. -Requires E-xD software version 2.60 or newer. Feature Add: Adds the ability to add and remove IP Camera settings for the E-MICRO 3.3 2018/12/06 Feature Add: Adds support for E-MICRO's that are updated to software version 3.7 or newer. Feature Add: Adds support for custom alert names in the E-MICRO-T(RHP). Bug Fix: Corrects a problem with the E-ACDCLM sensor being shown as an E-DUST sensor. Bug fix: Corrects a problem with adding, editing and deleting client user projects. 3.2 2018/09/24 Bug Fix: Corrects a problem with graphing E-MICRO integrated temperature sensors. Change: Changes the default server program administrative password to "nti". 3.1 2018/07/19 Feature Add: Adds support for viewing the E-MICRO Alert Thresholds. Feature Add: Adds the ability to roll (log rotate) and purge Event, System, and Alert logs. Feature Add: Adds support for HTTP authentication of IP Sensors and IP Cameras. Note: This requires E-xD software version 2.54 or newer to work. Feature Add: Adds support for the extended SMS and extended Schedule settings. Note: This requires E-xD software version 2.54 or newer to work. Feature Change: Changes the default security certificates to TLS. Note: This requires E-xD software version 2.54 or newer to work. Improvement: Improves the scrolling behavior of the User editor window, and the Summary Monitor window. Improvement: Improves the Sensor Configuration editor window to display better on lower resolution monitors. Improvement: Improves the ability of the Server to re-acquire a unit that has been non-responsive or has been lost due to network errors. Bug Fix: Corrects a problem with polling E-16D units with E-DI16DO16 units connected to ports 9 thru 16. Bug Fix: Corrects a problem with adding new units via command line. Bug Fix: Corrects a problem with group settings for User editing, SMS messages, Internal Sensors, External Sensors, and E-DI16DO16 Sensors. NOTE: It is recommended that the Server PC and any Client PC be running the same version of Java. 3.0 2017/07/31 Feature Add: Adds support for the E-MICRO-T(RHP) and E-1W. Feature Add: Adds support for the following sensors: E-STHSM & E-STSM E-STHS-PRC & E-STHS-PRCIND-100 E-STHS-LCD E-STHS-B E-ACLM -V & -P Frequency E-S5VDC E-S420MA Limited support for: E-ACDCLM E-DCLM-6 E-ACLM-3P480 Sensors can be monitored and Alerts can be acknowledged or dismissed only. Feature Add: Adds Datalog support Improvement: Improves the E-MNG stability with connected devices. Provides a more reliable connection with the E-xD and IPDU units. Improvement: Improves connectivity between the server and client programs. Improvement: Corrects bad values in some sensor graphs. Note: For full feature support of E-MNG version 3.0, E-xD units must be running firmware version 2.46 or later. 2.7 2017/02/03 Improvement: Changes the Unit loading sequences. This is to reduce system load which improves overall performance of the Management Software Improvement: Corrects a problem with installing the software license on newer operating systems and with newer versions of Java. Feature Add: Adds logging of system data and alerts. Software generates system.log and alerts.log text files accessible using Windows Explorer. Improvement: Improves the IP camera function start-up and reduces image flicker. Feature Add: Adds the “Group” name to the top of the Global Scrolling Summary page. 2.6 2016/08/11 Feature Add: Adds support for the E-AV-LC Air Velocity Sensor Feature Add: Adds the Enterprise Name for each unit to the Scrolling Global Summary page Both the Client and the Server program versions 2.6 must be used together. Neither can be used with earlier versions of the Client or Server program. 2.5 2016/04/22 Feature Add: Adds scalable sizes for custom display Feature Add: Adds an automatic save of the dashboard configuration upon closure of the Client program Feature Change: Changes the rights of the non-administrative user to include sensor monitoring only. The user can no longer make changes to any sensor or device settings. Bug Fix: Fixes a problem with adding and configuring IP Devices (This requires an update to the E-xD firmware (Version 2.33 or newer)) Feature Add: Adds the ability to edit users from the Client program. 2.4 2015/01/05 Bug Fix: Corrects a problem with editing users for groups of units. Only the Client program was updated in this release. The Server program is still at version 2.3. 2.3 2013/08/15 Feature: Adds notes for alerts, these can be unique for each user. Feature: Adds support for the E-STHS-PRC sensor. Bug Fix: Corrects a problem with the client properly recognizing a second Dew Point sensor Bug Fix: Corrects a problem with graphing Dew Point and Tachometer inputs. 2.2 2013/07/24 Feature: Adds support for preserving the graph data when the Client program is not running. Feature: Adds support for the E-STHS-IND Temperature / Humidity sensor Feature: Adds support for the Tachometer input. Feature: Adds an audio notification when a pop-up alert occurs. Bug Fix: Corrects a problem with the Server and Client program running properly on Java version 1.7 2.1 2013/03/18 Feature: Adds support for the IPDU-S4 and S8 Feature: Full support for E-2D (models with Rev C pcb only (2 power input jacks instead of 1)). Feature: Adds support for the E-DI16DO16(R)Digital Input / Output Expander Feature: Adds Unit and Global Scrolling Summary pages. Feature: Adds Sensor Graphing. Bug Fix: Corrects a problem with the Client program running properly when used on a user account without Administrative privileges. 2.0 2012/12/03 Features Added: Added support for E-16D and limited support for E-2D. Adds pop-up alert window Adds global summary views to groups. Adds command line configuration capability to the server software. Adds the ability to configure the server program from the client program. Adds the ability to run the server software without the GUI interface. Adds compatibility with Java version 7. 1.2 2010/02/12 Added support for E-LIS Light Intensity Sensor. Improved communication control allows the user to switch between SNMP v2c and SNMP v3 from within the E-MS-SEMS client software without having to restart the server. 1.1 2010/01/26 Added support for SNMPv3. Bug Fix: E-SEMS-16 firmware version 3.3 causes a loss in power sensor communication with the MS-SEMS version 1.0 software. This has been corrected. Bug Fix: The management software would continue to report errors from an IP device that had been removed from a E-SEMS-16 unit. This has been corrected. 1.0 2009/10/09 Initial Revision