ENVSEMS2D DEFINITIONS ::= BEGIN IMPORTS NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, Integer32 FROM SNMPv2-SMI DisplayString, TEXTUAL-CONVENTION FROM SNMPv2-TC; UtfDisplay ::= TEXTUAL-CONVENTION DISPLAY-HINT "t" STATUS current SYNTAX DisplayString envSems MODULE-IDENTITY LAST-UPDATED "201403251400Z" ORGANIZATION "Network Technologies Inc." CONTACT-INFO "Network Technologies Inc. Postal: 1275 Danner Dr, Aurora, OH 442022 US Tel: 330-562-7070 Fax: 330-562-1999 WEB: www.networktechinc.com" DESCRIPTION "ENVIROMUX-SEMS-2D MIB file." REVISION "201403251400Z" DESCRIPTION "Rev. 1.02- added support to change relay status using SNMP" REVISION "201211121400Z" DESCRIPTION "Rev. 1.01 - added remote inputs and remote relays" REVISION "201201050000Z" DESCRIPTION "Rev. 1.00 - initial version" ::= { hardware 9 } -- the root of the subtree for Network Technologies Inc nti OBJECT IDENTIFIER ::= { enterprises 3699 } -- subtree for products products OBJECT IDENTIFIER ::= { nti 1 } hardware OBJECT IDENTIFIER ::= { products 1 } software OBJECT IDENTIFIER ::= { products 2 } otherProduct OBJECT IDENTIFIER ::= { hardware 200 } -- ipdus2 subtree masterUnit OBJECT IDENTIFIER ::= { envSems 1 } envTraps OBJECT IDENTIFIER ::= { envSems 100 } hostSystem OBJECT IDENTIFIER ::= { masterUnit 1 } users OBJECT IDENTIFIER ::= { masterUnit 2 } groups OBJECT IDENTIFIER ::= { masterUnit 3 } dewPointSensors OBJECT IDENTIFIER ::= { masterUnit 4 } extSensors OBJECT IDENTIFIER ::= { masterUnit 5 } digInputs OBJECT IDENTIFIER ::= { masterUnit 6 } ipDevices OBJECT IDENTIFIER ::= { masterUnit 7 } outRelays OBJECT IDENTIFIER ::= { masterUnit 8 } pwrSupplies OBJECT IDENTIFIER ::= { masterUnit 9 } events OBJECT IDENTIFIER ::= { masterUnit 10 } smartAlerts OBJECT IDENTIFIER ::= { masterUnit 11 } remoteInputs OBJECT IDENTIFIER ::= { masterUnit 12 } remoteRelays OBJECT IDENTIFIER ::= { masterUnit 13 } envGroups OBJECT IDENTIFIER ::= { masterUnit 200 } -- groups sysGroup OBJECT-GROUP OBJECTS { sysTime, sysEnterpriseName, sysEnterpriseLocation, sysEnterpriseContact, sysEnterprisePhone } STATUS current DESCRIPTION "System parameters group" ::= {envGroups 1} extSensorsGrp OBJECT-GROUP OBJECTS { extSensorIndex, extSensorType, extSensorDescription, extSensorConnector, extSensorGroupNb, extSensorGroup, extSensorValue, extSensorUnit, extSensorUnitName, extSensorStatus, extSensorMinThreshold, extSensorMaxThreshold } STATUS current DESCRIPTION "External sensors group" ::= {envGroups 3} digInputsGrp OBJECT-GROUP OBJECTS { digInputIndex, digInputType, digInputDescription, digInputConnector, digInputGroupNb, digInputGroup, digInputValue, digInputStatus, digInputNormalValue } STATUS current DESCRIPTION "Dry contacts group" ::= {envGroups 5} ipDeviceGrp OBJECT-GROUP OBJECTS { ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceGroupNb, ipDeviceGroup, ipDeviceTimeout, ipDeviceRetries, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "IP devices group" ::= {envGroups 6} outRelaysGrp OBJECT-GROUP OBJECTS { outRelayIndex, outRelayDescription, outRelayStatus } STATUS current DESCRIPTION "Dry contacts group" ::= {envGroups 7} miscTrapFields OBJECT-GROUP OBJECTS { envTrapDescription, envTrapValue } STATUS current DESCRIPTION "General Information Traps" ::= {envGroups 8} extSensorTrapGrp NOTIFICATION-GROUP NOTIFICATIONS { extSensor1Trap, extSensor2Trap, extSensor3Trap, extSensor4Trap } STATUS current DESCRIPTION "External Sensors Traps Group" ::= {envGroups 10} digInputTrapGrp NOTIFICATION-GROUP NOTIFICATIONS { digInput1Trap, digInput2Trap, digInput3Trap, digInput4Trap, digInput5Trap } STATUS current DESCRIPTION "External Sensors Traps Group" ::= {envGroups 12} ipDeviceTrapGrp NOTIFICATION-GROUP NOTIFICATIONS { ipDevice1Trap, ipDevice2Trap, ipDevice3Trap, ipDevice4Trap, ipDevice5Trap, ipDevice6Trap, ipDevice7Trap, ipDevice8Trap, ipDevice9Trap, ipDevice10Trap, ipDevice11Trap, ipDevice12Trap, ipDevice13Trap, ipDevice14Trap, ipDevice15Trap, ipDevice16Trap } STATUS current DESCRIPTION "IP Device Traps Group" ::= {envGroups 13} miscNotificationGrp NOTIFICATION-GROUP NOTIFICATIONS { evLogFileTrap, dataLogFileTrap, remoteDataLogFileTrap} STATUS current DESCRIPTION "Other Traps Group" ::= {envGroups 14} pwrSuppliesGrp NOTIFICATION-GROUP OBJECTS { pwrSupplyIndex, pwrSupplyStatus } STATUS current DESCRIPTION "Power supplies group" ::= {envGroups 15} -- hostSystem subtree sysTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "System time" ::= { hostSystem 1 } sysEnterpriseName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Enterprise Name" ::= { hostSystem 2 } sysEnterpriseLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Enterprise Location" ::= { hostSystem 3 } sysEnterpriseContact OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Enterprise Contact" ::= { hostSystem 4 } sysEnterprisePhone OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Enterprise Phone" ::= { hostSystem 5 } -- external Dew point sensors description dewPointSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF DewPointSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Dew point sensors entries" ::= { dewPointSensors 1 } dewPointSensorEntry OBJECT-TYPE SYNTAX DewPointSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A dew point sensor entry" INDEX { dewPointSensorIndex } ::= { dewPointSensorTable 1 } DewPointSensorEntry ::= SEQUENCE { dewPointSensorIndex Integer32, dewPointSensorType INTEGER, dewPointSensorDescription DisplayString, dewPointSensorConnector Integer32, dewPointSensorGroupNb Integer32, dewPointSensorGroup DisplayString, dewPointSensorValue INTEGER, dewPointSensorUnit Integer32, dewPointSensorUnitName DisplayString, dewPointSensorStatus INTEGER, dewPointSensorMinThreshold Integer32, dewPointSensorMaxThreshold Integer32 } dewPointSensorIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of the Dew point sensor entry 1..4" ::= { dewPointSensorEntry 1 } dewPointSensorType OBJECT-TYPE SYNTAX INTEGER { undefined(0), dewPoint(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "Dew point Sensor Type" ::= { dewPointSensorEntry 2 } dewPointSensorDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Dew point Sensor Description" ::= { dewPointSensorEntry 3 } dewPointSensorConnector OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Connector where the Dew point sensor is attached" ::= { dewPointSensorEntry 4 } dewPointSensorGroupNb OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Dew point Sensor's Group" ::= { dewPointSensorEntry 5 } dewPointSensorGroup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Dew point Sensor's Group Name" ::= { dewPointSensorEntry 6 } dewPointSensorValue OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the Dew point sensor reading. It is presented in tenths of degrees" ::= { dewPointSensorEntry 7 } dewPointSensorUnit OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "The measuremnet unit for this sensor. Can be Celsius or Fahrenheit" ::= { dewPointSensorEntry 8 } dewPointSensorUnitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The measuremnet unit for this sensor in readable format" ::= { dewPointSensorEntry 9 } dewPointSensorStatus OBJECT-TYPE SYNTAX INTEGER {notconnected(0), normal(1), prealert(2), alert(3), acknowledged(4), dismissed(5), disconnected(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the Dew point sensor" ::= { dewPointSensorEntry 10 } dewPointSensorMinThreshold OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor lower threshold" ::= { dewPointSensorEntry 11 } dewPointSensorMaxThreshold OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor upper threshold" ::= { dewPointSensorEntry 12 } -- external sensors description extSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF ExtSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of external Sensors entries" ::= { extSensors 1 } extSensorEntry OBJECT-TYPE SYNTAX ExtSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An external sensor entry" INDEX { extSensorIndex } ::= { extSensorTable 1 } ExtSensorEntry ::= SEQUENCE { extSensorIndex Integer32, extSensorType INTEGER, extSensorDescription DisplayString, extSensorConnector Integer32, extSensorGroupNb Integer32, extSensorGroup DisplayString, extSensorValue INTEGER, extSensorUnit Integer32, extSensorUnitName DisplayString, extSensorStatus INTEGER, extSensorMinThreshold Integer32, extSensorMaxThreshold Integer32 } extSensorIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of the external sensor entry 1..4" ::= { extSensorEntry 1 } extSensorType OBJECT-TYPE SYNTAX INTEGER { undefined(0), temperature(1), humidity(2), power(3), lowVoltage(4), current(5), aclmvVoltage(6), aclmpVoltage(7), aclmpPower(8),water(9), smoke(10), vibration(11), motion(12), glass(13), door(14), keypad(15), panicButton(16), keyStation(17), digInput(18), light(22), tempHum(513), custom(32767), temperatureCombo(32769), humidityCombo(32770) } MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Type" ::= { extSensorEntry 2 } extSensorDescription OBJECT-TYPE SYNTAX UtfDisplay MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Description" ::= { extSensorEntry 3 } extSensorConnector OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Connector where the sensor is attached" ::= { extSensorEntry 4 } extSensorGroupNb OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor's Group" ::= { extSensorEntry 5 } extSensorGroup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor's Group Name" ::= { extSensorEntry 6 } extSensorValue OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the external sensor reading. For temperature, voltage, current or low voltage, it is presented in tenths of degrees/volts" ::= { extSensorEntry 7 } extSensorUnit OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "The measuremnet unit for this sensor. It is important only for temperature" ::= { extSensorEntry 8 } extSensorUnitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The measuremnet unit for this sensor in readable format" ::= { extSensorEntry 9 } extSensorStatus OBJECT-TYPE SYNTAX INTEGER {notconnected(0), normal(1), prealert(2), alert(3), acknowledged(4), dismissed(5), disconnected(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the sensor" ::= { extSensorEntry 10 } extSensorMinThreshold OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor lower threshold" ::= { extSensorEntry 11 } extSensorMaxThreshold OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor upper threshold" ::= { extSensorEntry 12 } extSensorAclmTable OBJECT-TYPE SYNTAX SEQUENCE OF ExtSensorAclmValues MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of external Sensors entries" ::= { extSensors 2 } extSensorAclmValues OBJECT-TYPE SYNTAX ExtSensorAclmValues MAX-ACCESS not-accessible STATUS current DESCRIPTION "An external sensor entry" INDEX { extSensorAclmIndex } ::= { extSensorAclmTable 1 } ExtSensorAclmValues ::= SEQUENCE { extSensorAclmIndex Integer32, extSensorPeakValue Integer32, extSensorFrequency Integer32, extSensorCurrent Integer32, extSensorSpikes Integer32, extSensorSwells Integer32, extSensorSags Integer32, extSensorRelay INTEGER } extSensorAclmIndex OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the sensor in the list" ::= { extSensorAclmValues 1 } extSensorPeakValue OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The peak value of the ACLM sensor presensted in tenths of volts/watts" ::= { extSensorAclmValues 2 } extSensorFrequency OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency measured by the ACLM sensor presensted in tenths of Hz" ::= { extSensorAclmValues 3 } extSensorCurrent OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current measured by the ACLM sensor presensted in tenths of A(mpers)" ::= { extSensorAclmValues 4 } extSensorSpikes OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of spikes read" ::= { extSensorAclmValues 5 } extSensorSwells OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of swells read" ::= { extSensorAclmValues 6 } extSensorSags OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sags read" ::= { extSensorAclmValues 7 } extSensorRelay OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Relay status" ::= { extSensorAclmValues 8 } -- dry contacts description digInputTable OBJECT-TYPE SYNTAX SEQUENCE OF DryContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of external Sensors entries" ::= { digInputs 1 } digInputEntry OBJECT-TYPE SYNTAX DryContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A dry contact entry" INDEX { digInputIndex } ::= { digInputTable 1 } DryContactEntry ::= SEQUENCE { digInputIndex Integer32, digInputType INTEGER, digInputDescription DisplayString, digInputConnector Integer32, digInputGroupNb Integer32, digInputGroup DisplayString, digInputValue INTEGER, digInputStatus INTEGER, digInputNormalValue INTEGER } digInputIndex OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of the external sensor entry 1..4" ::= { digInputEntry 1 } digInputType OBJECT-TYPE SYNTAX INTEGER { digInput(18) } MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Type. Only dry contact type will be used" ::= { digInputEntry 2 } digInputDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Description" ::= { digInputEntry 3 } digInputConnector OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Connector where the sensor is attached" ::= { digInputEntry 4 } digInputGroupNb OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor's Group" ::= { digInputEntry 5 } digInputGroup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor's Group Name" ::= { digInputEntry 6 } digInputValue OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the dry contact reading." ::= { digInputEntry 7 } digInputStatus OBJECT-TYPE SYNTAX INTEGER {notconnected(0), normal(1), prealert(2), alert(3), acknowledged(4), dismissed(5), disconnected(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the sensor" ::= { digInputEntry 8 } digInputNormalValue OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The normal value of the dry contact reading" ::= { digInputEntry 9 } -- remote inputs description remoteInputTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Remote Inputs entries" ::= { remoteInputs 1 } remoteInputEntry OBJECT-TYPE SYNTAX RemoteInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A remote input entry" INDEX { remoteInputIndex } ::= { remoteInputTable 1 } RemoteInputEntry ::= SEQUENCE { remoteInputIndex Integer32, remoteInputType INTEGER, remoteInputDescription DisplayString, remoteInputConnector Integer32, remoteInputGroupNb Integer32, remoteInputGroup DisplayString, remoteInputValue INTEGER, remoteInputStatus INTEGER, remoteInputNormalValue INTEGER } remoteInputIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of the remote input entry 1..4" ::= { remoteInputEntry 1 } remoteInputType OBJECT-TYPE SYNTAX INTEGER { remoteInput(18) } MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Type. Remote input contact type will be used" ::= { remoteInputEntry 2 } remoteInputDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Description" ::= { remoteInputEntry 3 } remoteInputConnector OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "Connector where the sensor is attached" ::= { remoteInputEntry 4 } remoteInputGroupNb OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor's Group" ::= { remoteInputEntry 5 } remoteInputGroup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor's Group Name" ::= { remoteInputEntry 6 } remoteInputValue OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the remote input reading." ::= { remoteInputEntry 7 } remoteInputStatus OBJECT-TYPE SYNTAX INTEGER {notconnected(0), normal(1), prealert(2), alert(3), acknowledged(4), dismissed(5), disconnected(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the sensor" ::= { remoteInputEntry 8 } remoteInputNormalValue OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The normal value of the remote input reading" ::= { remoteInputEntry 9 } -- IP Devices description ipDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF IpDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of IP Devices entries" ::= { ipDevices 1 } ipDeviceEntry OBJECT-TYPE SYNTAX IpDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IP Device entry" INDEX { ipDeviceIndex } ::= { ipDeviceTable 1 } IpDeviceEntry ::= SEQUENCE { ipDeviceIndex Integer32, ipDeviceAddress DisplayString, ipDeviceDescription DisplayString, ipDeviceGroupNb Integer32, ipDeviceGroup DisplayString, ipDeviceTimeout Integer32, ipDeviceRetries Integer32, ipDeviceValue INTEGER, ipDeviceStatus INTEGER } ipDeviceIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of the IP Device entry 1..8" ::= { ipDeviceEntry 1 } ipDeviceAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IP Device URL" ::= { ipDeviceEntry 2 } ipDeviceDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IP Device Description" ::= { ipDeviceEntry 3 } ipDeviceGroupNb OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the group the IP Device belongs to" ::= { ipDeviceEntry 4 } ipDeviceGroup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the group the IP Device belongs to" ::= { ipDeviceEntry 5 } ipDeviceTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "IP Device ping timeout (in seconds)" ::= { ipDeviceEntry 6 } ipDeviceRetries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of ping retries to the IP device, until responding" ::= { ipDeviceEntry 7 } ipDeviceValue OBJECT-TYPE SYNTAX INTEGER { notResponding(0), responding(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Responding status" ::= { ipDeviceEntry 8 } ipDeviceStatus OBJECT-TYPE SYNTAX INTEGER {notconnected(0), normal(1), prealert(2), alert(3), acknowledged(4), dismissed(5), disconnected(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm status of the IP Device" ::= { ipDeviceEntry 9 } -- outRelays description outRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF OutRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of output relays" ::= { outRelays 1 } outRelayEntry OBJECT-TYPE SYNTAX OutRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An output relay entry" INDEX { outRelayIndex } ::= { outRelayTable 1 } OutRelayEntry ::= SEQUENCE { outRelayIndex Integer32, outRelayDescription DisplayString, outRelayStatus INTEGER } outRelayIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of relay" ::= { outRelayEntry 1 } outRelayDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Desciption/name associated with the output relay" ::= { outRelayEntry 2 } outRelayStatus OBJECT-TYPE SYNTAX INTEGER { active(0), inactive(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the output relay" ::= { outRelayEntry 3 } -- remoteRelays description remoteRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of remote relays" ::= { remoteRelays 1 } remoteRelayEntry OBJECT-TYPE SYNTAX RemoteRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An output relay entry" INDEX { remoteRelayIndex } ::= { remoteRelayTable 1 } RemoteRelayEntry ::= SEQUENCE { remoteRelayIndex Integer32, remoteRelayDescription DisplayString, remoteRelayStatus INTEGER } remoteRelayIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of relay" ::= { remoteRelayEntry 1 } remoteRelayDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Desciption/name associated with the remote relay" ::= { remoteRelayEntry 2 } remoteRelayStatus OBJECT-TYPE SYNTAX INTEGER { active(0), inactive(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the remote relay" ::= { remoteRelayEntry 3 } -- powerSupply description pwrSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF PwrSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of power supplies" ::= { pwrSupplies 1 } pwrSupplyEntry OBJECT-TYPE SYNTAX PwrSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An output relay entry" INDEX { pwrSupplyIndex } ::= { pwrSupplyTable 1 } PwrSupplyEntry ::= SEQUENCE { pwrSupplyIndex Integer32, pwrSupplyStatus INTEGER } pwrSupplyIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of power supply" ::= { pwrSupplyEntry 1 } pwrSupplyStatus OBJECT-TYPE SYNTAX INTEGER { failed(0), ok(1), na(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the output relay" ::= { pwrSupplyEntry 2 } -- events description eventTable OBJECT-TYPE SYNTAX SEQUENCE OF EventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of events" ::= { events 1 } eventEntry OBJECT-TYPE SYNTAX EventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An event entry" INDEX { eventIndex } ::= { eventTable 1 } EventEntry ::= SEQUENCE { eventIndex Integer32, eventDescription DisplayString, eventStatus INTEGER } eventIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of the event" ::= { eventEntry 1 } eventDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Desciption/name associated with the event" ::= { eventEntry 2 } eventStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), alert(3), acknowledged(4), dismissed(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the event" ::= { eventEntry 3 } -- smartAlerts description smartAlertTable OBJECT-TYPE SYNTAX SEQUENCE OF SmartAlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of smartAlerts" ::= { smartAlerts 1 } smartAlertEntry OBJECT-TYPE SYNTAX SmartAlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A smartAlert entry" INDEX { smartAlertIndex } ::= { smartAlertTable 1 } SmartAlertEntry ::= SEQUENCE { smartAlertIndex Integer32, smartAlertDescription DisplayString, smartAlertStatus INTEGER } smartAlertIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of the smartAlert" ::= { smartAlertEntry 1 } smartAlertDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Desciption/name associated with the smartAlert" ::= { smartAlertEntry 2 } smartAlertStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), alert(3), acknowledged(4), dismissed(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the smartAlert" ::= { smartAlertEntry 3 } -- Trap Definitions extSensorsTraps OBJECT IDENTIFIER ::= { envTraps 5 } waterSensorsTraps OBJECT IDENTIFIER ::= { envTraps 6 } digInputsTraps OBJECT IDENTIFIER ::= { envTraps 7 } ipDevicesTraps OBJECT IDENTIFIER ::= { envTraps 8 } outRelaysTraps OBJECT IDENTIFIER ::= { envTraps 9 } envTrapDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Message issued together with the trap to explain the reason the trap was sent" ::= { envTraps 100 } envTrapValue OBJECT-TYPE SYNTAX Integer32 (-1000..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Message issued together with the trap to retrieve a value" ::= { envTraps 101 } -- sensor traps -- External sensors traps extSensor1Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, extSensorIndex, extSensorDescription, extSensorValue, extSensorUnitName, extSensorStatus } STATUS current DESCRIPTION "Trap issued when external sensor 1 (Connector #1) has a notification to send" ::= {extSensorsTraps 0 1 } extSensor2Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, extSensorIndex, extSensorDescription, extSensorValue, extSensorUnitName, extSensorStatus } STATUS current DESCRIPTION "Trap issued when external sensor 2 (Connector #1) has a notification to send" ::= {extSensorsTraps 0 2 } extSensor3Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, extSensorIndex, extSensorDescription, extSensorValue, extSensorUnitName, extSensorStatus } STATUS current DESCRIPTION "Trap issued when external sensor 3 (Connector #2) has a notification to send" ::= {extSensorsTraps 0 3 } extSensor4Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, extSensorIndex, extSensorDescription, extSensorValue, extSensorUnitName, extSensorStatus } STATUS current DESCRIPTION "Trap issued when external sensor 4 (Connector #2) has a notification to send" ::= {extSensorsTraps 0 4 } -- Dry contacts traps digInput1Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, digInputIndex, digInputDescription, digInputValue, digInputStatus } STATUS current DESCRIPTION "Trap issued when dry contact 1 (Connector #1) has a notification to send" ::= {digInputsTraps 0 1 } digInput2Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, digInputIndex, digInputDescription, digInputValue, digInputStatus } STATUS current DESCRIPTION "Trap issued when dry contact 2 (Connector #2) has a notification to send" ::= {digInputsTraps 0 2 } digInput3Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, digInputIndex, digInputDescription, digInputValue, digInputStatus } STATUS current DESCRIPTION "Trap issued when dry contact 3 (Connector #3) has a notification to send" ::= {digInputsTraps 0 3 } digInput4Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, digInputIndex, digInputDescription, digInputValue, digInputStatus } STATUS current DESCRIPTION "Trap issued when dry contact 4 (Connector #4) has a notification to send" ::= {digInputsTraps 0 4 } digInput5Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, digInputIndex, digInputDescription, digInputValue, digInputStatus } STATUS current DESCRIPTION "Trap issued when dry contact 5 (Connector #5) has a notification to send" ::= {digInputsTraps 0 5 } -- IP Devices traps ipDevice1Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #1 has a notification to send" ::= { ipDevicesTraps 0 1 } ipDevice2Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #2 has a notification to send" ::= { ipDevicesTraps 0 2 } ipDevice3Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #3 has a notification to send" ::= { ipDevicesTraps 0 3 } ipDevice4Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #4 has a notification to send" ::= { ipDevicesTraps 0 4 } ipDevice5Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #5 has a notification to send" ::= { ipDevicesTraps 0 5 } ipDevice6Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #6 has a notification to send" ::= { ipDevicesTraps 0 6 } ipDevice7Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #7 has a notification to send" ::= { ipDevicesTraps 0 7 } ipDevice8Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #8 has a notification to send" ::= { ipDevicesTraps 0 8 } ipDevice9Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #9 has a notification to send" ::= { ipDevicesTraps 0 9 } ipDevice10Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #10 has a notification to send" ::= { ipDevicesTraps 0 10 } ipDevice11Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #11 has a notification to send" ::= { ipDevicesTraps 0 11 } ipDevice12Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #12 has a notification to send" ::= { ipDevicesTraps 0 12 } ipDevice13Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #13 has a notification to send" ::= { ipDevicesTraps 0 13 } ipDevice14Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #14 has a notification to send" ::= { ipDevicesTraps 0 14 } ipDevice15Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #15 has a notification to send" ::= { ipDevicesTraps 0 15 } ipDevice16Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, ipDeviceIndex, ipDeviceAddress, ipDeviceDescription, ipDeviceValue, ipDeviceStatus } STATUS current DESCRIPTION "Trap issued when IP device #16 has a notification to send" ::= { ipDevicesTraps 0 16 } -- Output Relay trap outRelay1Trap NOTIFICATION-TYPE OBJECTS { envTrapDescription, outRelayIndex, outRelayDescription, outRelayStatus } STATUS current DESCRIPTION "Trap issued when output relay changes it's status" ::= { outRelaysTraps 0 1 } -- Event Log file trap evLogFileTrap NOTIFICATION-TYPE OBJECTS { envTrapDescription } STATUS current DESCRIPTION "Trap issued when the system has an event log file notification to send" ::= { envTraps 0 10 } -- Data Log file trap dataLogFileTrap NOTIFICATION-TYPE OBJECTS { envTrapDescription } STATUS current DESCRIPTION "Trap issued when the system has a data log file notification to send (file almost full)" ::= { envTraps 0 11 } remoteDataLogFileTrap NOTIFICATION-TYPE OBJECTS { envTrapDescription, envTrapValue } STATUS current DESCRIPTION "Trap issued when the system has a data log file reading to send" ::= { envTraps 0 12 } END