E-16D/-5D/-2D FIRMWARE RELEASE NOTES Last Update 2024/04/05 This listing provides the version number of the NTI E-16D / E-5D / E-2D Enterprise Environment Monitoring System firmware file, the date of the release, and a summary of the changes in that release. Note: If you have a unit with version 4.15 (or newer) installed, do not downgrade to an earlier version (before 4.15) of firmware or the internal temperature/humidity sensor will not work properly. Note: If you have a unit with version 4.0 (or newer) installed, this CANNOT be downgraded to an earlier version (before 4.0) of firmware. Note: It is recommended that any units upgrading from version 2.x or 3.x upgrade directly to version 4.5 or newer. 4.26 2024/04/04 Feature Add: Added support for E-CO2-THS Carbon Dioxide (CO2)/Temperature/Humidity/Dew Point Sensor. 4.25 2024/02/14 Feature Add: Improved modem log messages and added a button to log connection status. Feature Add: Provides additional delimiter formats (Space Delimited, CSV, or Tab Delimited) for the USB datalog and event log. Note: This needs to be set before the log entries are added, not during download. Feature Change: Provides the ability to use the + character as a prefix in phone numbers. Feature Change: Improves the resolution of the E-ACLM-3P480 sensors. Bug Fix: Corrects a problem with the E-DCLM-6 showing wrong values as associated sensors for sensor # 3,4,5,6. Bug Fix: Modem randomly fails to send SMS messages even if the signal is good. Bug Fix: Corrects a problem with CMS errors when sending PDU SMS. Bug Fix: SSH/RS232 Menu does not display modem data settings properly. Bug Fix: Upgraded OPENSSH to version 8.3 to fix security issues. Bug Fix: Upgraded Jquery to version 3.5 to fix security issues. Bug Fix: USB datalogs were not listed by modified date. Bug Fix: Improved web server stability when scanned with network scanner. 4.24 2023/05/26 Feature Add: Provides support for the E-ACDCLM Rev A boards. E-ACDCLM sensors manufactured after 5/26/23 need firmware version 4.24 or newer to operate. 4.23 2023/04/19 Feature Add: Provides support for editing the Maximum and Minimum Temperature & Dew Point values as displayed in the sensor status bar for the IP sensors. Feature Add: Provides support for integer values and a separate unit for allExternalSensors (allExternalSensorIntValue) in the SNMP MIB files. Note: MIB files have been updated to v1-22 to support this change. Feature Add: Provides support for IP Sensor to be displayed on the E-PLSD. Feature Change: Disables old insecure ciphers by default, does not require using the Enable Security setting. Bug Fix: Corrects a problem with the E-4GU-5 modems not responding properly to the Cell provider setups. Bug Fix: Corrects a problem with the IP Sensor status pages displaying "N/A" instead of the sensor value. Bug Fix: Corrects a problem with the IP Sensor graphs not clearing. Bug Fix: Corrects a problem with IP sensor offsets not working. Bug Fix: Corrects a problem with the inability to view the USB Event logs from the web page. 4.22 2022/12/22 Feature Add: Provides support for graphing internal sensors. Feature Add: Provides the option to automatically turn OFF the siren/beacon after a specified amount of time. Feature Add: Provides a colored legend for the sensor alert schedule table, the user schedule table, and changes the enabled color to green. Bug Fix: Corrects a problem with sensors on E-1W IP Sensors not graphing. Bug Fix: Corrects a problem with the inability to change the console RS232 baud rate on an E-5D. The E-5D must be rebooted to implement the changes. Bug Fix: Corrects a problem with the Android App not working with versions 3.x and newer software. Bug Fix: Corrects a problem with warning notifications (Email, SMS, SNMP Traps, Syslog) that were received even though only alert notifications was enabled. Bug Fix: Corrects a problem with the SNMP default port which was 0 after restore defaults instead of port 161. 4.21 2022/11/10 Feature Add: Provides support for the E-4GU-1 Modem. Feature Add: Provides the ability to clear the data log on E-16DEL (extended memory version) to allow for faster startups after reboot. Feature Change: Improves the reliability of the web server on public networks. Bug Fix: Corrects a problem with the data log randomly being cleared after a reboot. Bug Fix: Corrects a problem with the E-4GU-5 Modem not sending SMS messages reliably. Bug Fix: Corrects a problem with USB Modems not recovering a data connection after a disconnect. Bug Fix: Corrects a problem with IP filter rules not being re-enabled after reboot. 4.20 2022/09/09 Feature Add: Provides support for the IP Sensors (E-MICRO/1W) on MODBUS. Bug Fix: Corrects a problem with the Web login randomly not working after reboot. Bug Fix: Corrects a problem with the Beacon and Siren not being powered ON by E-1W IP Sensor alerts. Bug Fix: Corrects a problem in Events where the "Event to Acknowledge" list is empty. 4.19 2022/08/19 Feature Change: Provides support for the automatic configuration reload feature on the E-MNG-SH ENVIROMUX Management Software. Bug Fix: Corrects a problem with the Oauth popup for Gmail authentication getting blocked by browser security. Bug Fix: Corrects an intermittent problem with Gmail alert messages not being sent. Feature Change: Limits the test e-mails to users with e-mail address enabled only. 4.18 2022/05/31 Feature Change: Changes the XOAUTH feature to work with Google's updated security for Gmail. Feature Change: Changes the datalog e-mail feature to send datalog data even when the user schedule is OFF. Feature Change: Disables auto fill of passwords when enhanced security is enabled. Bug Fix: Corrects a problem with the E-xD not capturing images from E-IPCAM-DHNO-V2P camera when digest authentication is used. 4.17 2022/04/27 Bug Fix: Corrects a problem with the E-xD sending incorrect Engine ID information when using the SHA authentication protocol for SNMPv3 traps. Bug Fix: Corrects a problem with the E-xD not saving SNMPv3 user settings properly. 4.16 2022/04/12 Security Update: Add security updates for the web browser and other vulnerabilities. Bug Fix: Corrects a problem with using the ":" Character in passwords causing the inability to log into the device. 4.15 2022/03/23 Feature Change: Provides support for the new internal temperature / humidity sensor. Feature Add: Provides support for IP Sensors in the HTTP API feature. Bug Fix: Corrects a problem with RJ45 Digital Input alerts not triggering the alert scan list for the E-PLSD. Bug Fix: Corrects a problem with the SNMP Aux/Aux2 unit name fields being empty in some cases. 4.14 2022/03/10 Feature Add: Provides support for MQTT The user can receive sensor values at set intervals or when the sensor goes into alert, even when the ENVIROMUX is behind a firewall or router. Feature Add: Provides the ability to Acknowledge / Dismiss sensor warnings. Feature Change: Provides the ability to change the polling rate of the Digital Inputs Bug Fix: Corrects a problem with sensor viewing page refresh rates not being set properly. Bug Fix: Corrects a problem with contact sensors on RJ45 port triggering Output Relay before alert delay. Bug Fix: Correct a problem with the IP Sensor name not being displayed in e-mail alerts 4.13 2021/12/08 Bug Fix: When Radius authentication is enabled, the device would also ask for the client certificate when using HTTPS which would cause the login to fail. This has been corrected. 4.12 2021/11/19 Bug Fix: Corrects a problem where the E-PLSD sensor short names cannot be enabled for edit and display 4.11 2021/11/16 Feature Add: Provides the option to change the port number for SNMP and SNMP traps. 4.10 2021/11/05 Bug Fix: Corrects a problem with the Brief E-mail feature not working correctly. 4.9 2021/10/26 Feature Add: Provides the ability to send the datalog in bulk via e-mail. Note: This feature is not available on the E-16DEL model Feature Add: Provides the ability to execute SSH commands as non-root user on a remote machine. Feature Add: Provides the ability to completely disable HTTP when "Enable HTTP Access" is not selected and Network Security is selected. Feature Add: Provides the ability to change the root user name for added security. Feature Add: Provides the ability to change the SYSLOG port number. Feature Add: Provides the ability to send alert emails to multiple e-mail addresses (up to 4 addresses) for each user. Bug Fix: Corrects a problem with Digital Input descriptions not being correct on cascaded units. Bug Fix: Corrects a problem with SNMP alerts sending SMS messages without being selected. Bug Fix: Corrects a problem with the E-3P480 Apparent Power not displaying the correct range. 4.8 2021/09/17 Bug Fix: Corrects a problem introduced in v4.7 with the Digital Input status page not reporting the correct sensor status. 4.7 2021/09/03 Feature Add: Provides support for the E-PLSD. Bug Fix: Corrects a problem with E-4GU-6 modem not sending Chinese characters. Feature Improvement: Improved WEB security. Bug Fix: Corrects a problem with the Maps Configuration upload and save function not giving the acknowledgement messages. 4.6 2021/07/19 Bug Fix: Corrects a problem with the master unit not handling cascaded unit sensor alerts properly. Bug Fix: Corrects a problem with the Web Server function crashing after a Test SMS message is selected. Bug Fix: Corrects a problem with USB Modems not being loaded properly after a reboot or power cycle. 4.5 2021/06/07 Feature Add: Provides the ability to turn on or off the E-ACLM-P Power Relay Bug Fix: Corrects a problem with system configurations not importing properly when upgrading from version 2.x software to version 3.x or 4.1 thru 4.4 software. Bug Fix: Corrects a problem with units failing to reboot from the web interface. Feature Change: Change the Text Menu Option name "Delete 3.0 Configuration" to "Delete JSON Configuration" . The associated behavior of the function remains unchanged. 4.4 2021/05/06 Feature Add: Provides support for the E-4GU-6 Modem. 4.3 2021/03/19 Bug Fix: Corrects a problem with the Web interface service stopping, causing the loss of HTTP/HTTPS access. 4.2 2021/03/10 Bug Fix: Corrects a problem with the Event function "When triggered, acknowledge the following event" not being saved after a reboot. Bug Fix: Corrects a problem with SNMP Sensor Events. When string values are selected the entry is not displayed properly while being edited. 4.1 2021/03/03 Feature Add: Additional support for the E-MNG-SH software Note: The E-xD will need this update to work properly with the E-MNG-SH. Feature Add: Adds Support for temperature & humidity offset on External Sensors. Feature Add: Support for user password restrictions Feature Change: Sending status of IP Devices and sending confirmation status on acknowledge/dismiss of alerts in HTTP API Feature Change. Provides the ability to set the logs in reverse chronological order. Bug Fix: Output Relay status does not show custom status names. Bug Fix: Bad passwords cause the configuration to not load properly. Bug Fix: Deleting a user in the middle of a list and rebooting deletes the following users as well. Bug Fix: Deleting a digital input does not delete its corresponding events. Bug Fix: Email alert message is not sent for SMS delivery failure 4.0 2021/01/20 Change: Flash chip on circuit has been changed due to previous chip being at end-of-life. No change in features from version 3.9. NOTE: If firmware is upgraded to 4.0 (or newer), firmware CANNOT be downgraded to earlier version than 4.0. 3.9 2020/11/23 Feature Add: Adds support for SNMP sensors in HTTP API. Bug Fix: Corrects a problem with uploading HTTPS certificates. Bug Fix: Corrects a problem with changing user passwords through SSH console. 3.8 2020/11/06 Feature Add: Adds support for password encryption security. (Support for FIPS 198-1 password security.) Passwords in downloaded configuration file will now be encrypted. Feature Add: Adds support for one E-RJ8-RS485 Sensor Port Hub on an E-2D and two E-RJ8-RS485 Sensor Port Hubs on an E-5D. Improvement: Corrects a problem with using IP cameras on newer browsers (security issue). Improvement: Corrects a problem with adding, saving and viewing maps when adding more than 22 sensors. Bug Fix: Corrects a problem with the maximum voltage limit not saved properly on the E-ACLM-3P480. Bug Fix: Corrects a problem with the Delta / Wye configuration not being properly saved on an E-ACLM-3P480. Bug Fix: Corrects a problem with initial current transformer values not being correctly saved on an E-ACLM-3P480. Bug Fix: Corrects a problem with power supply sensors not sending SMS messages on alert with no custom SMS settings. 3.7 2020/09/28 Bug Fix: Corrects a problem with incorrect default values when adding a new RJ45 Dry Contact. 3.6 2020/09/18 Bug Fix: Corrects a problem with external sensors locking up / not updating after reboot. Bug Fix: Corrects a problem with random characters appearing in the Holiday Schedule. 3.5 2020/09/04 Feature Change: Enhances the sensor maps normal status color (uses a brighter green) for better visibility. Bug Fix: Corrects a problem with re-loading the IP Sensor configurations during software upgrades. 3.4 2020/08/17 Feature Add: Adds 4G Modem Data support for all current E-4GU models. Feature Add: Adds sensor mapping support. Feature Add: Adds the ability to redirect to a requested page, if left blank the default is the Summary page. Feature Change: Replaces the Sensor and User schedule with a graphic user interface. Feature Change: Adds a block addressing mode for MODBUS (instead of the sequential addressing). Feature Change: Adds a custom status messages for the Digital Inputs (instead of just open / closed). Feature Change: Changes the SMTP encryption selection to a drop down menu. Feature Change: Allows the E-RJ8-RS485 connection on any of the 16 sensor ports of an E-16D. The limit is still a maximum of 3 sensor hubs. Feature Change: Adds additional support for the E-ACLM-(V)(P) sensor in the E-MNG software. Feature Change: Changes the JSON configuration file to work with the E-MNG-SH software. Feature Change: Changes the internal configuration of the IP Cameras within the firmware (behind the scenes). NOTE: The following features / functions will be returned to default condition if the unit is "downgraded" to an earlier version of software: • IP Sensor configurations • SMTP Encryption settings • User & Sensor Schedule settings • IP Camera settings. It is recommended that a configuration backup be performed prior to upgrading to version 3.4 3.3 2020/06/18 Bug Fix: SMS phone numbers were not imported in versions 3.0 through 3.2 (from versions 2.6x) Bug Fix: Corrects a problem with user passwords getting corrupted in versions 3.0 thru 3.2 Bug Fix: Corrects a problem with several settings not being saved or updated when migrating to version 3.x software: • Internal / External custom SMS messages • Remote Output Relay; Alert flags • Contact Sensors (digital inputs); global change status • Events; remote SSH commands Bug Fix: Corrects a problem with E-ACLM-(V)(P) sensors not sending the frequency value in e-mail alerts. Bug Fix: Corrects a problem with the IP Sensor external sensor graphs not working. 3.2 2020/05/13 Bug Fix: Corrects a problem with user settings for LDAP that were not saved correctly. 3.1 2020/04/30 Bug Fix: Corrects a problem with Smart Alert Events for E-DI16DO16, Dry Contacts, and IP Sensors becoming corrupted after an update. This problem originated in firmware version 2.61 Bug Fix: Corrects a problem with the E-DCLM-6 configuration becoming corrupted upon updating to firmware version 3.0. Feature Add: Provides the ability via Text Menu to clear the 3.0 configuration file, reload the 2.x configuration file and convert it automatically to the new 3.x JSON file format. For instructions, visit www.networktechinc.com/pdf/how-to-reload-2x-configuration-file.pdf, once the unit has been upgraded from version 3.0 to version 3.1. If you have upgraded directly from version 2.x to version 3.1, this conversion will be done automatically and no further action is necessary. 3.0 2020/04/14 Feature Add: Adds support for the E-RJ8-RS485 sensor hub. This is only supported on the E-16D ports 1 thru 3 Feature Change: Changes the SNMP structures: • Adds a new "allExternalSensors" group which includes sensor already in "extSensors", "auxSensors", "aux2Sensors", “remoteInputs”, “remoteRelays”. • New SNMP MIB file still supports the original sensors groups for External, Aux, Aux2 including Remote DI16DO(R)16 sensor group so that it continues to work with the E-MNG software and other software already integrated. But all new releases/changes of these software should use the “allExternalSensors” group as the old groups will be deprecated • SNMP Traps are moved to "allExternalSensors" eliminating Traps generated on "extSensors", "auxSensors", and "aux2Sensors". Note: MIB files have been updated to v1-21 for to support this change. Feature Changes: Changes the MODBUS feature to support the changes to the external sensor structure. • Adds monitoring of the power supplies. • Adds External Sensor status monitoring. • Corrects a problem with setting output relays active or inactive via MODBUS. • Adds the E-DI16DO(R)16 to the external sensors. • Changes the E-DI16DO(R)16 digital inputs and output relays to be read contiguously instead of hard to locate pre-designated address blocks for each sensor port. • Instructions on the changes and additions are in the updated E-xD manual. Feature Add: Adds an additional 10 sensors to the E-ACLM-3P480 on the summary web page. This includes the ability to configure alerts. New sensors include: • Frequency • Phase A, B, and C Phase Angle • Phase A, B, and C Power Factor • Phase A, B, and C Apparent Power Feature Add: Adds the ability to display other sensor's values on the E-STHS-LCDW display. This include sensors connected to cascaded units. Feature Add: Adds support for "timeticks" and "gauge32" devices in the SNMP Sensor feature. Feature Change: Changes the displayed model name of a unit from "ENVIROMUX-xD" to "E-xD". Feature Change: Changes the E-xD configuration file to a human readable JSON file format. The JSON configuration file can be edited using any word processor program (ie. Microsoft Word, Wordpad Notepad etc.) Feature Change: Changes the E-ACLM-V/P max voltage displayed on the summary page to 255VAC. Feature Change: Updates the HTTP API (REST API) for external sensors to include a unique ID for each external sensor and added another position variable. Bug Fix: Corrects a problem with NTP not syncing time properly on device startup. Bug Fix Corrects a problem with Ethernet slave sensor values not updating correctly when the communication is poor. Bug Fix: Corrects the temperature range for E-1W thermocouple type temperature sensors to -40º to 2500ºC. Bug Fix: Corrects a problem with non-admin users getting logged out when trying to go to the alerts page. Bug Fix: Corrects a problem when the datalog stops sending via SYSLOG due to an incorrect gateway. Bug Fix: Corrects a problem with some German translations. 2.62 2020/03/06 Feature change: Improves the color contrast when making selections in the menu. 2.61 2019/09/05 Feature Improvements: Fixes problems with the Modbus feature not supporting all current sensors: -Improves the mapping for supported sensors. -Adds updated mapping for the E-ACLM-3P480 and E-DCLM6. -Adds Tachometer on Digital Input 1 polling support. -Adds Beacon and Siren status polling support. -Corrects a problem with turning ON and OFF the Output Relays via Modbus. Feature Add: Adds the ability to poll remote devices via SNMP Note: MIB files have been updated to v1-20 to support this feature. Bug Fix: Corrects a problem with SNMPv3 Auth and Privacy keys needing to be the same. Bug Fix: Corrects a problem with E-1W when used as an IP Sensor showing incorrect Digital Input values. 2.60 2019/07/31 Feature Add: Adds support for E-1W IP sensors. Allows up to four (4) E-1W units to be added. Note: Sensor graphs cannot be viewed. Feature Add: Adds support for 4G SMS messages using E-4GU-1/2/3 modem. Feature Add: Added an optional customized banner message for the web login page. Allows for a maximum message length of 1500 characters. Feature Change: Adds the ability to display the E-ALDS lengths in metric units (Meters). Feature Add: Added support to power cycle digital inputs; Digital Input 1-8 "12V" on an E-16D or "AUX PWR" terminals on an E-5D or E-2D using the E-MNG software. Note: This feature works in conjunction with E-MNG software version 3.4 or later. Improvement: Increases the stability of the monitoring processes in high traffic networks. Bug Fix: Corrects a problem with the Discovery tool not finding a unit if the subnet information is incorrect. (This was broken in software version 2.59) Feature Removal: Removes support for the USB-LCD-7 which has been discontinued. 2.59 2019/06/06 Feature update: Support for updated ACDCLM sensor with improved accuracy for AC Voltage measurements Bug Fix: Corrects a problem with Custom SMS messages not working properly when brief e-mail messages are selected. Bug Fix: Corrects a problem with a 3G primary route reverting to a secondary route any time network settings are changed. Bug Fix: Corrects a problem with the Discovery tool not detecting the LAN connection when 3G data is set as the primary route. Bug Fix: Corrects a problem with the inability to view and download a USB data log file. (This was broken in version 2.58) Bug Fix Corrects a problem with cascaded slave power supply failures not enabling the Beacon / Siren ports. Bug Fix: Corrects a problem with SNMP traps for the E-DI16DO(R)16 Digital Inputs and Output Relays not being properly defined. Note: MIB files have been updated to v1-19 for to support this fix. Bug Fix: Corrects a problem with unclean exits from the text menu via SSH or Telnet causing performance issues. 2.58 2019/05/22 Feature Add: Adds critical process monitoring that will restart a crashed process eliminating the need for a system reboot. Feature Update: Upgrades SSH to the latest secure algorithms. Upgrades the TLS library for SSH and HTTPS. Note: Older versions of SSH clients will no longer work with the E-xD. Bug Fix: Corrects a problem with the inability to acknowledge or dismiss a digital input alarm via SNMP 2.57 2019/03/08 Feature Add: Support for Audible Alert notifications when viewing the Summary web page. Feature Add: Support for Test Email and Test SMS button. Feature Add: Support for overriding SMS format between Plain Text and PDU. Feature Add: Support for customized Power Supply descriptions. Feature Add: Support for customized SMS messages for power supplies. Feature Add: Displays modem signal strength in SSH/RS232 Text Menu. Feature Add: Support to enable and disable all alerts through web page (Alarm Information Page under Monitoring Menu). Feature Add: Support to enable and disable all alerts through RJ45 contact type sensors and Digital Inputs. Feature Improvement: Adds a record to the event log when an output relay status changes. Bug Fix: Corrects a problem with SMS alerts wherein sensors and IP device alerts did not have the same message format. Bug Fix: Corrects a problem with the custom SMS field not being saved for E-ACLM-3P480 sensor. Bug Fix: Corrects a problem with the displayed values for the E-ACLM-3P480 sensors in the SSH/RS232 Text menu. Bug Fix: Corrects a problem with the SMS Timestamp that was not working with some alerts. Bug Fix: Corrects a problem with Digital Inputs as Sensor values in Smart Alerts not working. Feature change: Updates the German Language translation for better accuracy. 2.56 2018/10/30 Bug Fix: Corrected reporting of leak location when E-ALDS sensor is used. 2.55 2018/10/23 Feature Add: Adds support for E-ALDS Addressable Leak Detection Sensor. Feature Add: Adds the ability to offset the internal temperature and humidity sensor values. Feature Add: Adds the ability to edit custom values for Digital Input and Output Relay alerts. Bug Fix: Corrects several errors in the SNMP MIB files. Bug Fix: Corrects a problem with Chinese language phrases in alert e-mails regarding Digital Inputs. Note: For full SNMP feature support use v1-18 or later MIB files for E-16D,E-5D and E-2D. 2.54 2018/07/17 Feature Add: Adds the ability to disable weak SSL cipher suites via web interface and the text menu. This also disables ICMP (ping) responses. This includes the ability to enable/disable weak ciphers via SNMP Feature Add: Adds DDNS support with several providers including No-IP, Dydns and FreeDNS Feature Change: Changes the default security for E-MNG and SMS Relay encryption to TLS. Feature Add: Adds support for E-MNG software to support IP Camera HTTP Authentication Feature Add: Adds support for E-MNG software to support Extended SMS and Extended Schedules Feature Change: Removes support for the E-1W as IP Sensors Bug Fix: Corrects a problem with controlling SMS settings via the text menu and in RADIUS. Bug Fix: Corrects a problem with the Master not updating the status of cascaded Slave units. Bug Fix: Corrects a problem with the MAC ID and Engine ID not being displayed with VLAN Tagging enabled. Note: For full SNMP feature support use v1-17 or later MIB files for E-16D and E-5D, and v1-16 or later for E-2D. 2.53 2018/04/09 Feature Add: Adds support for the E-1W as IP Sensors -Up to four E-1W units can be added as IP Sensors. -This is in addition to the eight E-MICRO units that can be added. Feature Add: Adds GUI interface control for the SSH / Telnet / Serial Interface timeout -Adds event logging of SSH / Telnet / Serial text menu access. Note: This update will require anyone already using the timeout in version 2.52 to re-configure the timeout in this version. (go to Administration > Network > Server Settings > Console Timeout) Feature Add: Adds support for the "Operator" level user in RADIUS. Feature Add: Adds support to add Digital Inputs & Remote Digital Inputs via the Text Menu. Feature Add: Adds the ability to change network settings via SNMP. Feature Add: Adds the ability to perform a system reset (reboot) via SNMP. Feature Add: Adds the ability to display device model, serial number, firmware revision, hardware revision, and manufacturer information via SNMP. Bug Fix: Corrects a problem with adding too many Smart Alerts when "Add a Smart Alert" is selected. Note: For full SNMP feature support use v1-16 or later MIB files for E-16D and E-5D, and v1-15 or later for E-2D. 2.52 2018/02/06 Feature Add: The ENVIROMUX now supports 802.1Q VLAN tagging which can be used on managed switches to get more bandwidth and improved security Feature Add: Adds the ability to control the siren and beacon ports on E-5D and E-16D directly via SNMP. Note: For this SNMP feature support use v1-15 or later MIB files for the E-5D and E-16D. Bug Fix: Corrects a problem with the inability to add new Smart Alerts. (This was broken in version 2.51) Bug Fix: Corrects a problem with Events associated with IP Devices and RJ45 Digital Inputs not working properly. Bug fix: Corrects a problem with Internal Sensor Alerts not working on Cascaded units. 2.51 2018/01/19 Feature Add: Adds support for JSON API to poll sensors using a HTTP or curl command. Feature Add: Adds Support for an "Operator" User with limited administrative permissions. Feature Add: Adds support for a timeout feature on the Text Menu SSH, Telnet, and Serial connection. This is fixed at 10 Minutes. Feature Add: Adds the ability to query and display the firmware version via SNMP. Feature Add: Adds the ability to use the E-xD as a SMS gateway via SNMP. Feature Add: Adds the ability to edit the Internal and External Sensor alert thresholds via SNMP Feature Add: Adds support for support for sensor based Smart Alert bypassing the sensor alerts selections and events. Feature Add: Adds support to generate an alert when a sensor is disconnected. Improvement: Makes "Auto Acknowledge" the default selection for sensor critical alert configurations. This is for Internal Sensors, External Sensors, Digital Inputs, and IP Devices Bug Fix: Corrects a problem with MIB file error on syntax checks. Bug Fix: Corrects a problem with power supply failure reporting via SYSLOG. Note: For full SNMP feature support use v1-14 or later MIB files. 2.50 2017/12/12 Feature Add: Adds support for 1.2 million data log entries on the expanded nand flash model E-16DEL The data log will not be lost after a power cycle or restart of the E-16DEL Feature Add: Increases the standard model's data log to 1724 entries. Bug Fix: Corrects a problem with “Cycle Sensor Power” selection not working. 2.48 2017/11/14 Bug Fix: Corrects a problem with updating the E-16D software via Web Update. 2.47 2017/10/12 Feature Add: Adds the ability to configure up to 4 SMS numbers per user. Feature Add: Adds SNMP set commands to acknowledge or dismiss Event alerts. Note: This requires the use of v1-12 or later MIB files. Feature Add: Improves the way flash drives are mounted or un-mounted from the E-xD. Feature Add: Adds the ability to store and view data logs on a flash drive. Feature Add: Adds the ability to store view IP Camera images on a flash drive. Feature Add: Adds the ability to save images from an IP Camera using a port other than Port 80. Improvement: Improves the User and Sensor Scheduling feature. Note: Any scheduling feature settings already configured will be lost. These will need to be re-entered after this update. Change: SNMP is now enabled by default. Bug Fix: Corrects a problem with losing the configuration ID of the E-STHSB. Bug Fix: Corrects a problem with incorrect trap OIDs on the E-5D internal sensors. Bug Fix: Corrects a problem with the web server locking up by the Qualys security scanner. Bug Fix: Corrects a problem with LDAP / RADIUS settings not being properly displayed. 2.46 2017/07/24 Feature Add: Adds support for monitoring total KWH on the E-ACLM-3P480. Note: This requires a firmware update to the ENVIROMXUX-ACLM-3P480 (update released on 6/26/17, must be done at factory). Bug Fix: Corrects a problem with losing the configuration on an E-DI16DO16 if the sensor is disconnected. Bug Fix: Corrects a problem with Smart Alert Events not sending alert e-mail messages. Bug Fix: Corrects a problem with mounting a flash drive at startup or reboot. Improvement: Improved connectivity with the E-MNG Management software. 2.45 2017/03/30 Feature Add: Adds support for IP camera authentication to send camera images via e-mail. Feature Add: Adds additional RADIUS support that allows updates to already existing users. An updated dictionary.nti file (found on our website) is also required. Improvement: Corrects a problem with Smart Alerts for cascaded RJ45 digital inputs. Bug Fix: Corrects a problem with missing SNMP v1 trap OIDs. 2.44 2017/02/09 Feature Add: Adds support for RADIUS Authentication Improvement: Changes the Alert E-Mail messages for Digital Inputs. Changes the messages to "Digital Input is in alarm status" and "Digital Input returned to normal status" 2.43 2017/01/13 Feature Add: Adds support for the E-ACLM-3P480 3-Phase Power Monitor Feature Add: Adds support for IP camera HTTP authentication. Bug Fix: Corrects a problem with adding slave unit sensor Smart Alert Events. Bug Fix: Corrects a problem with the System identifying itself properly as a E-16D single power unit during a power-up or reboot. SNMP support for the E-ACLM-3P480 requires mib file version 1.11 or later. 2.42 2016/11/18 Feature Add: Adds the ability to download the data log in CSV format Feature Add: Adds the ability to send e-mails in HTML format. Bug Fix: Corrects a problem with configuring the digital inputs on cascaded slave units. Bug Fix: Corrects a problem with the “Tach Sensor” function (used for E-WSS Wind Speed Sensor) on the E-16D Digital Input 1 that was not working. Bug Fix: Corrects a problem with sensor graphs not being cleared properly. 2.41 2016/09/09 Feature Add: Adds the ability to view Sensor Warnings (Non-Critical Threshold Values) via SNMP 2.40 2016/08/31 Improvement: Improves Sensor graphing by decreasing the margin for better resolution. Bug Fix: Corrects a problem with the SMS Relay function not working. (This was broken in version 2.34) Bug Fix: Corrects a problem with E-DCLM-6 sensors not being graphed on E-2D and -5D units. Bug Fix: Corrects a problem with port identification of the E-DCLM-6. Bug Fix: Corrects a problem with Digital Input status not being correctly reported upon start-up or reboot. 2.39 2016/08/11 Bug Fix: Corrects a problem with sending SMS alert messages in German. Bug Fix: Corrects a problem where E-DCLM-6 sensors are not being graphed. Bug Fix: Corrects a problem that causes the serial interface to randomly become uncontrollable. Bug Fix: Removes checkbox option for “Enable Siren/Beacon” from sensor configuration page for E-2D (this is not a feature on this model) Bug Fix: Corrects a problem in which the E-DI16DO16 is not initialized to normal status after performing a reboot of the E-xD. Bug Fix: Corrects a problem in alert email where DC current value was not reported. 2.38 2016/07/05 Bug Fix: Corrects a problem with IP Sensor alerts not activating the beacon or siren ports. Bug Fix: Corrects a problem with smart alerts not deactivating the associated output relay if acknowledged or the alert returns to normal. Bug Fix: Corrects a problem with adding an event for digital inputs or IP devices where the configuration page is not correct for the type of sensor being configured. Feature Add: Adds the ability for non-administrative users to view sensor graphs. Improvement: Corrects a problem where E-ACDCLM or E-DCLM-6 sensors are not being graphed. Improvement: Changes the display length of the e-mail subject line for sensor alerts to 60 characters. 2.37 2016/06/10 Feature Change: Improvements made to default settings of E-DCLM-6 when one is connected. 2.36 2016/04/18 Bug Fix: Corrects a problem with the serial port showing incorrect characters after logging into the text menu. (This was broken in version 2.35) Bug Fix: Corrects a problem with the inability of the IP Sensor alerts to control the Beacon or Siren ports. 2.35 2016/03/30 Adds support for E-ACLM-P18 AC Line Monitor. Adds support for the E-DCLM-6 sensor Feature Change: Adds TLS V1.2 and removes SSL for added security. This change creates 2 issues for users of the E-MNG Monitoring System Management Software: TLS Ver 1.2 requires the use of Java version 1.8 or newer Java version 1.8 eliminates SSL also which means the E-MNG software will no longer communicate with the old model E-SEMS-16(U) units Feature Change: Adds the ability to enable or disable the Output Relay Interlock. You can now choose to associate a single output relay with multiple alert sources if you want. Bug Fix: Corrects a problem with displaying the AC Current of an E-ACDCLM sensor, this was broken in firmware version 2.34 Note: If your network includes the use of the E-MNG Management Software and you are managing both old model (E-SEMS-16/-16U) and newer model (E-16D) units with it, you may not want to install this firmware upgrade. See changes detailed above. 2.34 2016/02/22 Bug Fix: Corrects several problems with alerts from Digital Inputs on Cascaded units, and associating Cascaded unit Output Relays. 2.33 2016/01/22 Bug Fix: Corrects a problem with IP Devices causing incorrect reporting of alerts. Feature Add: Adds support for E-STHS-LCD Feature Add: Adds support for the E-ACDCLM. Feature Add: Adds the ability to change the SYSLOG facility (Local0 to Local7) Feature Add: Changes the size of the sensor lists in the Text Menu to fit longer sensor names. Feature Change: Changes the “Add Associated Output Relay” drop list to only include those not currently in use. Note: If your configuration already has multiple associations for a single output relay, those associations will remain in place after this firmware update. However, you will not be able to configure more of them, and if you remove a multiple association after the update, you will not be able to re-instate it. If you need to configure an output relay to change state as a result of multiple sensor alert conditions, you can still configure Events and Smart Alerts to change a relay state based on multiple sensor alert conditions. Bug Fix: Corrects a problem with sending e-mails from remote output relays (DI16DO16 relays) Bug Fix: Corrects a problem with the RTD sensor not changing the display to “ºF” when selected. 2.30 2015/09/22 Bug Fix: Corrects a problem causing the failure of sensor graphs after 8 to 14 days of recording. Bug Fix: Corrects a problem with group assignments not working properly on Remote Output Relays. Bug Fix: Corrects a problem with "Invalid event ID" messages displayed in the events configuration page. 2.29 2015/08/27 Feature Add: Adds a separate Alert Summary page for showing only sensors that are in alert state. Feature Add: Adds alert configuration for ACLM-V/P Frequency measurement. Feature Add: Adds monitoring of the Power Supply Status to the Text Menu. Bug Fix: Corrects a problem with SNMP functionality. Connection to some DNS servers caused SNMP process failure. Bug Fix: Corrects a problem with data logging if an NTP server sends erroneous time. Note: In order for the E-xD to add the Frequency sensor of the E-ACLM-V/P to the list of sensors, any previously installed E-ACLM-V or ACLM-P must first be deleted from the E-xD Summary page (using the Web interface). Within 30 seconds the E-xD will re-sense the E-ACLM-V/P and will include the Frequency sensor in the list of sensors. All applicable sensors included with the E-ACLM-V/P (including Frequency Sensor(s)) will then be available for configuration. 2.28 2015/07/31 Feature Add: Adds higher security authentication for Gmail email accounts (XOAUTH2) 2.27 2015/03/10 Feature Add: Add the ability to send SMS messages when the Event & Data logs are 90% full. Bug Fix: Corrects a problem with Non-Admin user not being able to Acknowledge or Dismiss sensor alerts. 2.26 2015/02/11 Feature Add: Adds ability to send E-mail / Syslog / and SNMP alerts when the modem is lost or fails to send SMS. 2.25 2015/01/14 Feature Add: Adds a configurable delay of notification for lost slave connectivity (2 to 20 sec.). Feature Add: Adds the ability to turn ON and OFF Output Relays via IP Device alerts. Feature Add: Adds support for Modbus address 1 and 255. Feature Add: Adds graphing of slave unit sensors to the slave unit web page. Improvement: When an E-S60VDC is connected, the default values on channel 2 will now also apply to channel 1. Security Fix: Provides a fix for the Padding Oracle On Downgraded Legacy Encryption (Poodle) Vulnerability. Bug Fix: Corrects a problem with sensor scheduling when sensor alerts are still sent outside the active window. Bug Fix: Corrects a problem with non-administrative users getting "bumped" to the login screen. Bug Fix: Corrects a problem with the DNS Timeout setting not being properly saved. 2.24 2014/11/26 Feature Add: Adds support for IP Sensors (E-MICRO-T(RHP) Feature Add: Adds customizable SMS messages for all sensor types. Bug Fix: Corrects a problem with sensors from cascaded units not turning on the Siren and Beacon. Bug Fix: Corrects a problem with IP Devices not working properly when using Hostnames. Bug Fix: Fixes the problem with the E-16D units shutting down instead of remaining ON in battery mode when power is lost. 2.23 2014/10/27 Feature Add: Adds support for the E-RTDT-1562 sensor 2.22 2014/10/09 Feature Update: Adds SSL security updates Feature Add: Adds graphing for the E-WSS wind speed sensor on Digital Input 1 Feature Add: Adds support for the E-STHSM temperature / humidity sensors 2.20 2014/08/25 Feature Add: Adds the ability to turn OFF sensor graphing Bug Fix: Corrects a problem with graphing sensor data when using IE 6, 7, & 8, speeding up the presentation of the graph in the browser. Feature Add: Adds the offset correction factor for the Industrial Temperature Sensor to improve sensor accuracy 2.19 2014/07/28 Bug Fix: Corrects a problem with sending SMS messages from an E-3GU-IND modem on an E-2D or E-5D. 2.18 2014/07/01 Feature Add: Adds support for the E-STS-PRC Bug Fix: Corrects a problem with SNMP Traps sending the correct status value when returning to normal from an alert. 2.16 2014/05/08 Feature Add: Adds German language support. Feature Add: Adds System Information reporting via SNMP including CPU Usage and Memory Usage through the use of the UCD-SNMP-MIB file from UC, Davis which is maintained by the snmp-project. Bug Fix: Correct a problem with controlling Remote Output Relays via SNMP. 2.15 2014/03/24 Feature Add: Makes DHCP the default network setting. If no DHCP server is found, ENVIROMUX will revert to the static network settings. Feature Add: Adds configurable DNS timeout (for slow E-mail servers). Feature Add: Adds advanced LDAP settings for Microsoft Active Directory. Feature Add: Adds support for the Trendnet TV-IP672PI IP Camera. Bug Fix: Corrects a problem with turning ON the Beacon / Siren from a remote digital input. Bug Fix: Corrects a problem with the MIB files not compiling with some MIB browsers. Bug Fix: Changes the filtering of the Digital Inputs for the E-2D and E-5D to prevent false alerts from the E-SDS smoke detector. 2.14 2014/02/07 Feature Add: Adds support for the new Ipad APP – E-APP-IPAD Feature Add: Adds the ability to load a custom web server X509 certificate. Feature Add: Adds support for client certificate verification. Bug Fix: Corrects a problem with the system adding a DI16DO16 configuration where there isn't any connected Bug Fix: Corrects a problem with the E-MNG management software in that the software was not being able to read the sensor group names Bug Fix: Corrects a possible problem with sending SMS messages from USB Modems. Bug Fix: Corrects a problem with sensor and user scheduling. 2.13 2013/12/16 Feature Add: Adds the ability to control the output relays via SNMP. Feature Add: Changes the sensor schedule function to turn OFF associated relays when the sensor is not active 2.12 2013/12/03 Bug Fix: Corrects a problem with the E-3GU-IND modem randomly losing communication with the ENVIROMUX Monitoring System. 2.11 2013/11/21 Feature Add: Adds a separate return to normal delay in the Smart Alerts. This will allow for longer delays when associating Output Relays. Feature Add: Adds the ability to send remote commands via SSH. This feature is in Events and Smart Alerts section. Feature Add: Adds the ability to name sensor groups. Feature Add: Adds the ability to filter the information sent in an E-mail. Feature Add: Adds support for the TP-Link TL-SC3230N IP camera image captures. Bug Fix: Corrects a problem with the serial modem communication on the E-5D. Bug Fix: Corrects a problem Remote Serial Port on the E-5D where the user could connect to the device on the remote serial port but could not communicate with the device. Bug Fix: Corrects a problem with sensor scheduling on the Digital Inputs. Bug Fix: Corrects a problem with a Dew Point sensor alert triggering the Fault LED or the Beacon / Siren. Bug Fix: Corrects a problem with the Dew Point sensor graphing when the sensor is connected to a port other than port 1. 2.10 2013/10/25 Feature Add: Adds support for the E-DUST sensor. Change: Disables SSLV2.0 which is a security risk. Improvement: Corrects a problem that occurs when sensor thresholds are changed from the management software. Improvement: Corrects a problem with time zones that have 30 Minute settings (ie. +5:30 Time Zone). Improvement: Corrects a problem with displaying sensor graphs in Internet Explore 6,7 and 8. Bug Fix: Corrects a problem with the E-3GU-IND modem which was broken in version 2.5. 2.9 2013/09/13 Feature add: Adds support for Japanese language selection. Feature add: Adds ability to view power supply status from mobile page. Feature add: New main menu link provided to display power supply status summary. Bug Fix: Fixed a bug where internal humidity was wrong when internal temperature was displayed in Fahrenheit and correct when displayed in Centigrade. 2.8 2013/08/13 Feature add: Adds support for Cascading Up to Four Slaves can be either serial (RS485) or Ethernet cascaded E-2D and E-5D can only be cascaded using Ethernet method Maximum Serial Cable Length using Cat5e cable is 4000ft. Requires a 100Ω Terminating Plug for the last serial cascaded unit Feature add: Adds Modbus TCP support Feature add: Adds support to assign sensors to multiple groups Feature add: Adds schedule control to the sensors to control when sensors will respond to alert conditions Feature add: Adds Sensor recorded value Graphing Feature add: Adds support for remote serial port via SSH Feature add: Adds Event Log entries for SMS message status Feature add: Adds support for non-numeric characters in the SMS phone numbers Bug Fix: Corrects a memory leak in the Kernel 2.7 2013/06/03 Feature Add: Adds support for the E-STHS-IND Temperature / humidity sensor. Feature Change: Makes the E-WSS Wind Speed sensor the default association when the Tachometer on Digital Input 1 is added. Feature Change: Makes the default IP address 192.168.1.21 for all E-xD units. 2.6 2013/05/15 Feature Add: Adds support for a tachometer (i.e. E-WSS Wind Speed Sensor) to be connected to Digital Input 1. 2.5 2013/05/02 Feature Add: Adds support for the E-STHS-PRC precision temperature / humidity sensor. Feature Add: Adds support for the E-3G data connection. Bug Fix: Adds support for the new flash memory. Bug Fix: Corrects a problem with Dew Point sensor settings on the web page and in the text menu. 2.4 2013/03/11 Feature Add: Adds support for the E-TAB7 7 Inch Tablet. Feature Add: Added SMS relay feature- an E-xD unit with a GSM modem can be used by other E-xD units to send SMS messages. Bug Fix: Corrects a problem with serial modem support on the E-16D. 2.3 2013/02/14 Feature Add: Adds Support for the E-SDA Smoke Detector. Bug Fix: Corrects a problem with configuring Output Relays. Bug Fix: Corrects a problem with the Power Supply Alerts associating an Output Relay. Bug Fix: Corrects a problem with SNMP trap OID's. 2.1 2013/02/05 Feature Add: Adds Support for the E-2D(B) Rev C boards only The earlier versions of the E-2D(B) are not compatible with this version of firmware. TO IDENTIFY E-2D MADE WITH REV C PCB: These units include two 9VDC power input jacks instead of one. Feature Add: Adds the ability for to save camera images to the flash drive. Bug Fix: Fixed minor bugs related to event settings. 2.0 2013/01/11 Feature Add: Adds Support for the E-5D(B); This is now consolidated software to be used for the E-5D and E-16D. Feature Add: Adds Support for the DI16DO16(R) Digital Input / Output Expander. Feature Add: Adds the ability for one Event to acknowledge another Event. 1.3 2012/12/14 Feature Add: Adds RS232 serial modem support (model E-16D-RS only). Feature Add: Adds a pop-up confirmation window when deleting sensors. 1.2 2012/11/19 Feature Add: Adds support for the E-MNG Server Environment Monitoring Systems Management Software Feature Add: Adds TLS support to email SMTP server settings Bug Fix: This update also corrects a problem with adding double-function sensors when hot-plug is detected (the sensor in the next connector was being removed from the list). 1.1 2012/10/10 Feature Add: Adds a +12V interrupt to the Digital Inputs. This allows the user to momentarily power OFF a device connected to a Digital Input Feature Add: Adds a Restore Defaults push button Feature Add: Adds a Beacon & Siren Alarm Reset/Test push button 1.0 2012/08/13 Initial Revision