FIRMWARE RELEASE NOTES Last Update 2023/02/08 This listing provides the version number of the NTI PWR-RMT-RBT2-515R-LCV2 Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets, the date of the release, and a summary of the changes in that release. Note: Units that have only "PWR-RMT-RBT2-515R-LCV2" for the NTI part number with serial numbers 100-110 use "S02" firmware. v4 2023/02/08 (for "S02" models only) New Feature: Option to enter user’s HTTPS Certificate / Key. The Device will reboot, power output not affected. Certificate will be removed if the device is Reset to Factory Default. New Feature: New option for recurring schedule as: Repeat every XX day(s) from [yyyy/mm/dd] Feature Change: Changed the default number of times the outlet will power cycle from 1 time to 3 times when unable to ping a device. Feature Change: HTTP TCP detection to include ‘Host’. Feature Change: Cloud Server is Enabled by default. Feature Change: Removed function of “long press UIS button” and will auto assign a fixed LAN IP to a device. Feature Change: If the outlet is power cycled, the Uninterruptible Internet System (UIS) ping period will be disabled until the outlet is powered back ON, avoiding false positive failures. Feature Change: The Event Log default displayed "Type" was changed from "Status" to "All". Feature Change: Google Hangouts were removed. We will be switching to new Google Chat in upcoming firmware. Feature Change: GUI > Configuration > System Time > Time Server [Edit]. The Default to list up to 15 time servers. Now the User can add 5 more for a limit of 20 time servers. Feature Change: Modified device DST-server communications. Bug Fix: Fixed security vulnerability Bug Fix: Under "Email Notifications", when selecting the "Event" option and clicking Apply, the selection will now be retained. Bug Fix: Cloud connection needed to be manually restarted, if Skype Bot was initiated first. Bug Fix: UIS Reset time period was different if a ping response on a local device was different than a ping response on an internet-based device due to removal of the "Timeout" calculation. This was edited to synchronize the beginning of the Reset time period so the time period countdown would start at the same time whether there was a variation in the ping delay or not. Bug Fix: /goform/login outlet_status.xml does not need csrftoken Bug Fix: "manual time" failed to apply after system restarted. Bug Fix: Resolved GoAhead vulnerability. Bug Fix: Duplicate Gmail addresses causes “Delivery Status Notification (Failure)” message. Bug Fix: Fixed Yahoo Mail for when used with APP Password issue. v3 2020/10/21 New Feature: Support APIPA (Automatic Private IP Addressing). Feature Change: Enhancement to device-server communication stability. Bug fixes: Device 'Ping response' did not update correctly when offline. API command for Outlet "Off > On" not working. [UIS Reset] did not execute according to saved changes made to [Configuration] > [Website / IP Address] > [Assign]. Device unlinked from cloud account after a firmware upgrade. Port number setting when using Utility / Netility. Layout and display issue when viewing GUI on mobile browser. v2 2020/06/24 New Features: At first login (or after a Factory Reset) user needs to 'Create a new Administrator account'. New Login & Password (Set between 1 to 32 characters. { } < > " ' ; $ not allowed). Implemented "Cross-Site Request Forgery" (CSRF) prevention. [@79368266] Implemented Cookie-Login method New [Configuration] > [Timeout Settings] > [Detect unplugged LAN cable]. When [Enabled] 'Auto Reset' will be disabled if LAN cable is physically unplugged or there is no network signal in LAN. Updated [Timeout Settings] default settings and verbiage. Timeout for each website (TO): Default changed to 5sec The site will 'Timeout' if it does not respond within the set time. Set Ping Frequency (F): Default changed to 10sec Determine when the next ping is sent after each group's response or timeout. Number of Continuous Timeout Cycles (C): Default remains at 3x Number of continuous timeout cycles before UIS Reset is triggered. Ping Delay After UIS Reset (D): Default remains at 4min Set how long the device waits after an UIS Reset event before performing network checks. Number of UIS Reset (U): Default remains at 3x Set the number of UIS Reset attempts when internet connection is lost. Timeout calculations based on default settings: Each cycle duration = (TO x C) + (F x (C-1)) 1st UIS Reset: (5sec x 3)+(10sec x 2) = 35sec (max), 2nd UIS Reset: (60sec x 4min) + 35sec = 275sec (max) ...(U)th UIS Reset Provided the device is 'new' and not 'owned by cloud account', user can [Add] device using [Add by Serial Number] function without enabling [Cloud Service] function. Once a device is successfully 'Added', the [Cloud Service] function will be automatically [Enabled]. This function can only be attempted twice within each 3 minute cycle. Feature Changes: [Web] > [Network] > [Hostname]; added clickable link. Reworded [Web] > [Network] > [Hostname] > [Help]. [Web] > [Configuration] > [Website / IP Address] > text edited to state "Ping" & "HTTP", previously "UDP" & "TCP". Removed non-applicable [SMS] function. [Force UIS Reset] limited to a maximum of 4x resets. [Help] updated to read "Final: t3 + 10minutes". Replaced non-responsive www.bing.com with www.pingler.com Bug fixes: Icon on browser's tab keeps showing as loading. Outlets Off, reset device to factory default. Outlets turn On, but no output. v1 Initial Revision