Network Technologies Inc, Innovators in KVM SolutionsWelcome Return to NTI homepage
KVM
SWITCHES
CONSOLE
SWITCHES
KVM
SPLITTER
VIDEO
SWITCHES
VIDEO MATRIX
SWITCHES
VIDEO
SPLITTER
EXTENDERS
via CAT5
KVM
DRAWERS
MONITORS &
ACCESSORIES
SERVER
ENVIRONMENT
VIDEO
CONVERTERS
CABLES &
ADAPTERS


Knowledge Base Home » Knowledge Base Search

Knowledge Base Search

Use the form below to enter your search criteria. By default, all content is searched except for document comments. If you wish to search comments as well as everything else, click "Also Search Comments" below.

Enter Search Terms
Look For:
      [ Advanced Search | Tips ]
Welcome, Guest Help
Login Login
Click to change your viewing preferences Guest Settings


Search Results » 291 results for: Rackmux resolution issues Rank by:
Displaying results 241 - 255 Pages: [Previous | 1 ... 14 15 16 17 18 19 20 | Next ]
241) Document Type: General ST-C5V-600: Video Picture is not sharp or is smeared. 0%
  [1637] Comments: 0, Last Modified: Dec 7, 2012 1:31 PM - Find Similar  
  ST-C5V-600: Video Picture is not sharp or is smeared. Issue: Video Picture is not sharp or is smeared. Cause: CATx cable is too long. Solution: Verify length is within specified limits of 600 feet. OR Cause: Video not adjusted. Solution: Check cable connections and power cycle. If model has manual quality adjustment buttons on the remote unit, press the “+&rdquo  
242) Document Type: General ST-C5VA-300: No audio for models with audio support. 0%
  [1665] Comments: 0, Last Modified: Dec 7, 2012 2:04 PM - Find Similar  
  ST-C5VA-300: No audio for models with audio support. Issue: No audio for models with audio support. Cause: Audio cable is not properly plugged-in. Solution: Check all cable connections. OR Cause: Speakers are not plugged in. Solution: Verify speakers are connected and powered. OR Cause: CATx cable is not properly connected. Solution: Check CATx cable connections  
243) Document Type: General ST-C5VA-600: No audio for models with audio support. 0%
  [1645] Comments: 0, Last Modified: Dec 7, 2012 1:35 PM - Find Similar  
  ST-C5VA-600: No audio for models with audio support. Issue: No audio for models with audio support. Cause: Audio cable is not properly plugged-in. Solution: Check all cable connections. OR Cause: Speakers are not plugged in. Solution: Verify speakers are connected and powered. OR Cause: CATx cable is not properly connected. Solution: Check CATx cable connections  
244) Document Type: General ST-C6DVI-IR-300: Power LED does not illuminate. 0%
  [1724] Comments: 0, Last Modified: Aug 23, 2013 11:21 AM - Find Similar  
  ST-C6DVI-IR-300: Power LED does not illuminate. Issue: Power LED does not illuminate. Cause: Power supply is not connected or plugged-in. Solution: Make sure outlet is live and AC adapter is plugged-in (one for each Remote and Local Unit). Ensure that the 9V DC jack is fully connected.  
245) Document Type: General The mouse malfunctions when a MAC computer attached to a UNIMUX KVM Switch has its operating system upgraded. 0%
  [103] Comments: 0, Last Modified: Jan 21, 2009 2:28 PM - Find Similar  
  Issue: The mouse malfunctions (skips to the left corner and simulates a click and hold) when a MAC computer attached to a UNIMUX Matrix KVM Switch has its operating system upgraded from a MAC OS X10.3 (Panther) to a MAC OS X 10.4 (Tiger) Solution: Turn on the MAC mode on the UNIMUX Matrix KVM Switch. To do so, follow the steps below: Press Ctrl+ ~(tilde) to access the On Screen Display. Press  
246) Document Type: General The NTI Discovery Tool application does not detect any NTI devices 0%
  [119] Comments: 0, Last Modified: Feb 6, 2009 2:42 PM - Find Similar  
  Issue: The NTI Discovery Tool application does not detect any NTI devices. Cause: The NTI Discovery Tool does not detect devices located across sub-nets of a network. Example: A PC running the Discovery Tool application connected to a 192.168. 3 .XXX network will only search the 192.168. 3 .XXX sub-net for NTI devices and will not detect any NTI device connected to 192.168. 1 .XXX network. Solution  
247) Document Type: General The NTI Discovery Tool application does not detect any NTI devices 0%
  [120] Comments: 0, Last Modified: Feb 6, 2009 3:27 PM - Find Similar  
  Issue: The NTI Discovery Tool application does not detect any NTI devices. Cause: The NTI Discovery Tool does not detect devices located across sub-nets of a network. Example: A PC running the Discovery Tool application connected to a 192.168. 3 .XXX network will only search the 192.168. 3 .XXX sub-net for NTI devices and will not detect any NTI device connected to 192.168. 1 .XXX network. Solution  
248) Document Type: General Troubleshooting MRTG Configuration Problems 0%
  [188] Comments: 0, Last Modified: Jul 23, 2010 10:03 AM - Find Similar  
  Issue: The mrtg config file Generated for ENVIROMUX using the on-line available config generator script gives an error "Unknown SNMP var". Solution: Make sure mib file path and mib file name specified at line "LoadMibs:" in config file are correct. If snmp v3 support is enabled while installing net-snmp then add line "EnableSNMPv3: yes" in the generated mrtg config script below  
249) Document Type: General UNIMUX KVM Switches (Single-User and Multi-User): The user port seems to be locked up, mouse no longer moves even when user is switched to another CPU port. 0%
  [189] Comments: 0, Last Modified: Aug 11, 2010 11:08 AM - Find Similar  
  Issue: 4-port and above UNIMUX-USBV-x, UNIMUX-USBV-xHD KVM Switches, and UNIMUX-nXm-U, UNIMUX-nXm-UHD KVM Matrix Switches: The user port seems to be locked up, mouse no longer moves even when user is switched to another CPU port. Cause: Broadcast mode may have been inadvertently turned ... for the same issue.  
250) Document Type: General UNIMUX-2X8-U (serial # 288 and lower) & UNIMUX-4X8-U (serial # 251 and lower) : Keyboard and mouse occasionally fail on random user ports 0%
  [45] Comments: 0, Last Modified: Jan 21, 2009 2:21 PM - Find Similar  
  Issue: Keyboard and mouse occasionally fail on random user ports Cause: One of the user ports may fail, causing both the keyboard and mouse connected to that user port to lock up, while the remaining user ports continue to work properly. By turning the unit off and on, the problem will be fixed temporarily, but the keyboard and mouse could potentially lock up again. Solution:For UNIMUX-2X8-U (with serial  
251) Document Type: General UNIMUX-2X8-U (serial # 288 and lower) & UNIMUX-4X8-U (serial # 251 and lower) : The video occasionally fails on random user ports 0%
  [51] Comments: 0, Last Modified: Jan 21, 2009 2:25 PM - Find Similar  
  Issue: The video occasionally fails on random user ports Cause: The video signal is lost, resulting in the monitor screen going black. The signal will be lost on both user ports at the same time. By turning the unit off and on, it may randomly fix the problem. Solution:For UNIMUX-2X8-U (with serial number 288 and lower) and UNIMUX-4X8-U (with serial number 251 and lower), the unit needs a hardware  
252) Document Type: General UNIMUX-DVI-2, UNIMUX-DVI-xHD: The mouse malfunctions when attached to a SUN or PS/2 computer. 0%
  [1957] Comments: 0, Last Modified: Nov 27, 2013 10:47 AM - Find Similar  
  or PS/2 computer. Issue: The mouse malfunctions when attached to a SUN or PS/2 computer. Cause  
253) Document Type: General UNIMUX-nXm-UHD, UNIMUX-nXm-U: The mouse malfunctions when attached to a SUN or PS/2 computer. 0%
  [1958] Comments: 0, Last Modified: Nov 27, 2013 10:54 AM - Find Similar  
  New Roman";} Issue: The mouse malfunctions when attached to a SUN or PS/2 computer. Cause  
254) Document Type: General UNIMUX-USBV-xO, UNIMUX-USBV-xHD: The mouse malfunctions when attached to a SUN or PS/2 computer. 0%
  [1956] Comments: 0, Last Modified: Nov 27, 2013 10:45 AM - Find Similar  
  :"Times New Roman";} Issue: The mouse malfunctions when attached to a SUN or PS/2 computer. Cause  
255) Document Type: General UNIMUX-USBV-xUO: The front push buttons do not work. 0%
  [156] Comments: 0, Last Modified: Jan 21, 2009 2:46 PM - Find Similar  
  Issue: The front push buttons do not work. Cause: The user is not authorized to access the switch unless logged in. OR The ?Cascade? DIP switches on the front panel of the switch are not all set to the ?OFF? position. Solution: When a standard user powers up the system, a security screen will appear if security has been enabled by the administrator. If the screen saver is on, disable the screen saver  