Network Technologies Inc, Innovators in KVM SolutionsWelcome Return to NTI homepage
KVM
SWITCHES
CONSOLE
SWITCHES
KVM
SPLITTER
VIDEO
SWITCHES
VIDEO MATRIX
SWITCHES
VIDEO
SPLITTER
EXTENDERS
via CAT5
KVM
DRAWERS
MONITORS &
ACCESSORIES
SERVER
ENVIRONMENT
VIDEO
CONVERTERS
CABLES &
ADAPTERS


Knowledge Base Home » Knowledge Base Search

Knowledge Base Search

Use the form below to enter your search criteria. By default, all content is searched except for document comments. If you wish to search comments as well as everything else, click "Also Search Comments" below.

Enter Search Terms
Look For:
      [ Advanced Search | Tips ]
Welcome, Guest Help
Login Login
Click to change your viewing preferences Guest Settings


Search Results » 188 results for: sensor Rank by:
Displaying results 121 - 135 Pages: [Previous | 1 ... 6 7 8 9 10 11 12 13 | Next ]
121) Document Type: FAQ E-LDx-y: How can I test the Liquid Detection Sensor and how often should I test it? 5%
  [1871] Comments: 0, Last Modified: Feb 7, 2018 11:21 AM - Find Similar  
  E-LDx-y: How can I test the Liquid Detection Sensor and how often should I test it? We recommend testing your leak detection system at least once a year, although some applications may require more frequent testing. System testing should include the following points: With the system powered up, ensure no alarms are present on the system. If the liquid detection rope is installed  
122) Document Type: FAQ E-16D: How Many E-MICRO Units can be Connected to an E-16D Master/Slave Cascade Configuration 1%
  [2085] Comments: 0, Last Modified: Jan 31, 2018 10:49 AM - Find Similar  
  E-MICRO IP Sensors can be connected to the configuration. This is because IP Sensor configuration can only be done through the E-16D Master unit, which allows for up to eight connected IP Sensors. NOTE: Sensors connected to the E-MICRO units can be monitored on the E-16D Master unit.  
123) Document Type: FAQ E-2D: How Many E-MICRO Units can be Connected to an E-2D Master/Slave Cascade Configuration 1%
  [2087] Comments: 0, Last Modified: Feb 7, 2018 10:02 AM - Find Similar  
  E-2D: How Many E-MICRO Units can be Connected to an E-2D Master/Slave Cascade Configuration When configuring an advanced Master and Slave cascade, a maximum of eight E-MICRO IP Sensors can be connected to the configuration. This is because IP Sensor configuration can only be done through the E-2D Master unit, which allows for up to eight connected IP Sensors. NOTE: Sensors connected to the E  
124) Document Type: FAQ E-5D: How Many E-MICRO Units can be Connected to an E-5D Master/Slave Cascade Configuration 1%
  [2086] Comments: 0, Last Modified: Feb 7, 2018 11:12 AM - Find Similar  
  E-5D: How Many E-MICRO Units can be Connected to an E-5D Master/Slave Cascade Configuration When configuring an advanced Master and Slave cascade, a maximum of eight E-MICRO IP Sensors can be connected to the configuration. This is because IP Sensor configuration can only be done through the E-5D Master unit, which allows for up to eight connected IP Sensors. NOTE: Sensors connected to the E  
125) Document Type: FAQ E-MICRO: How Many E-MICRO Units can be Connected to an E-xD Master/Slave Cascade Configuration 1%
  [2088] Comments: 0, Last Modified: Feb 7, 2018 10:34 AM - Find Similar  
  E-MICRO: How Many E-MICRO Units can be Connected to an E-xD Master/Slave Cascade Configuration When configuring an advanced Master and Slave cascade, a maximum of eight E-MICRO IP Sensors can be connected to the configuration. This is because IP Sensor configuration can only be done through the E-xD Master unit, which allows for up to eight connected IP Sensors. NOTE: Sensors connected  
126) Document Type: General E-16D: Beacon not illuminating 1%
  [1581] Comments: 0, Last Modified: Jan 31, 2018 10:45 AM - Find Similar  
  E-16D: Beacon not illuminating Issue: Beacon not illuminating. Cause: Wires are not connected properly. Solution: Check wire connections. OR Cause: Beacon in use is improperly rated. Solution: Make sure Beacon is rated at 12VDC, 180mA or less. OR Cause: Sensor is not configured to power ON beacon. Solution: Check sensor configuration. Ensure Beacon is selected  
127) Document Type: General E-16D: Siren not making noise 1%
  [1582] Comments: 0, Last Modified: Jan 31, 2018 10:45 AM - Find Similar  
  E-16D: Siren not making noise Issue: Siren not making noise. Cause: Wires are not connected properly Solution: Check wire connections. OR Cause: Siren in use is improperly rated. Solution: Make sure Siren is rated at 12VDC, 180mA or less. OR Cause: Sensor is not configured to power ON siren. Solution: Check sensor configuration. Ensure Siren is selected under  
128) Document Type: General E-5D: Beacon not illuminating 1%
  [1815] Comments: 0, Last Modified: Feb 7, 2018 11:09 AM - Find Similar  
  E-5D: Beacon not illuminating Issue: Beacon not illuminating. Cause: Wires are not connected properly. Solution: Check wire connections. OR Cause: Beacon in use is improperly rated. Solution: Make sure Beacon is rated at 12VDC, 180mA or less. OR Cause: Sensor is not configured to power ON beacon. Solution: Check sensor configuration. Ensure Beacon is selected  
129) Document Type: General E-5D: Siren not making noise 1%
  [1816] Comments: 0, Last Modified: Feb 7, 2018 11:09 AM - Find Similar  
  E-5D: Siren not making noise Issue: Siren not making noise. Cause: Wires are not connected properly Solution: Check wire connections. OR Cause: Siren in use is improperly rated. Solution: Make sure Siren is rated at 12VDC, 180mA or less. OR Cause: Sensor is not configured to power ON siren. Solution: Check sensor configuration. Ensure Siren is selected under  
130) Document Type: FAQ E-MINI: Can the E-MINI trigger an external device, such as an alarm system? 1%
  [34] Comments: 0, Last Modified: Feb 7, 2018 10:57 AM - Find Similar  
  Can the E-MINI trigger an external device, such as an alarm system? The sensor ports on the E-MINI are only for receiving signals from an external device and cannot be used for sending signals. However, the E-REMS is capable of triggering an external device through its digital output ports.  
131) Document Type: FAQ E-MINI: How to set Mini Server Environment Monitoring System to send alert e-mails? 1%
  [155] Comments: 0, Last Modified: Feb 7, 2018 10:57 AM - Find Similar  
  How to set Mini Server Environment Monitoring System (E-MINI) to send alert e-mails? To get email alerts you need to configure the sensor. 1. Go to the configuration page of the sensor you want to have send alerts: 2. Ensure the E-mail box is checked. 3. Enter the email address into the "notify addresses" box. 4. Then apply the settings. 5. You can test your settings by selecting "  
132) Document Type: FAQ Can the ENVIROMUX Server Environment Monitoring System retransmit an alert at specific intervals defined by the user? 1%
  [102] Comments: 0, Last Modified: Feb 7, 2018 10:57 AM - Find Similar  
  Can the ENVIROMUX Server Environment Monitoring System retransmit an alert at specific intervals defined by the user? Yes, the ENVIROMUX Server Environment Monitoring System can be set to retransmit an alert until it is acknowledged, at specific intervals defined by the user. This can be set in the alert methods section of the configuration for each sensor. The minimum interval before an alert can  
133) Document Type: FAQ E-16D: How to Connect Multiple Smoke Detectors to a Single ENVIROMUX Unit Using the Digital I/O Expander. 1%
  [1891] Comments: 0, Last Modified: Jan 31, 2018 10:30 AM - Find Similar  
  unit's RJ45 sensor port using up to 500 feet of CAT5/5e/6 cable. Up to 16 additional smoke ... -SDS-CEPA Smoke Detector Sensor (CE) with an included power supply should be connected to the expander using 22-gauge 2-wire sensor cables . The power supply cable comes stripped and tinned ... as there are RJ45 sensor ports available. Other self-powered sensors, such as the E-IMD-P  
134) Document Type: FAQ E-16D: How to Connect Multiple Smoke Detectors to a Single ENVIROMUX Unit Using the Digital I/O Expander. 1%
  [1892] Comments: 0, Last Modified: Jan 31, 2018 10:40 AM - Find Similar  
  unit's RJ45 sensor port using up to 500 feet of CAT5/5e/6 cable. Up to 16 additional smoke ... -SDS-CEPA Smoke Detector Sensor (CE) with an included power supply should be connected to the expander using 22-gauge 2-wire sensor cables . The power supply cable comes stripped and tinned ... as there are RJ45 sensor ports available. Other self-powered sensors, such as the E-IMD-P  
135) Document Type: FAQ E-16D: How to Connect Multiple Smoke Detectors to a Single ENVIROMUX Unit Using the Digital I/O Expander. 1%
  [1890] Comments: 0, Last Modified: Jan 31, 2018 10:56 AM - Find Similar  
  's RJ45 sensor port using up to 500 feet of CAT5/5e/6 cable. Up to 16 additional smoke detectors ... -SDS-CEPA Smoke Detector Sensor (CE) with an included power supply should be connected to the expander using 22-gauge 2-wire sensor cables . The power supply cable comes stripped and tinned; follow ... sensor ports available. Other self-powered sensors, such as the E-IMD-P or E-CMD  