Network Technologies Inc, Innovators in KVM SolutionsWelcome Return to NTI homepage
KVM
SWITCHES
CONSOLE
SWITCHES
KVM
SPLITTER
VIDEO
SWITCHES
VIDEO MATRIX
SWITCHES
VIDEO
SPLITTER
EXTENDERS
via CAT5
KVM
DRAWERS
MONITORS &
ACCESSORIES
SERVER
ENVIRONMENT
VIDEO
CONVERTERS
CABLES &
ADAPTERS


Knowledge Base Home » Knowledge Base Search

Knowledge Base Search

Use the form below to enter your search criteria. By default, all content is searched except for document comments. If you wish to search comments as well as everything else, click "Also Search Comments" below.

Enter Search Terms
Look For:
      [ Advanced Search | Tips ]
Welcome, Guest Help
Login Login
Click to change your viewing preferences Guest Settings


Search Results » 291 results for: Rackmux resolution issues Rank by:
Displaying results 121 - 135 Pages: [Previous | 1 ... 6 7 8 9 10 11 12 ... 20 | Next ]
121) Document Type: General E-2D: Cannot access ENVIROMUX user interface with Ethernet connection via Telnet 0%
  [1678] Comments: 0, Last Modified: Feb 7, 2018 9:59 AM - Find Similar  
  E-2D: Cannot access ENVIROMUX user interface with Ethernet connection via Telnet Issue: Cannot access ENVIROMUX user interface with Ethernet connection via Telnet. Cause: Telnet not enabled. Solution: Enable Telnet through web interface. Via the web interface, select the “Network Configurations” page. Under “Server Settings,” place a checkmark in the box  
122) Document Type: General E-2D: Cannot get Discovery Tool to work 0%
  [1680] Comments: 0, Last Modified: Feb 7, 2018 9:58 AM - Find Similar  
  E-2D: Cannot get Discovery Tool to work Issue: Cannot get Discovery Tool to work. Cause: Java Runtime Environment not installed. Solution: Install Java Runtime Environment. Go to http://java.com/en/download/index.jsp Download and install the Java Runtime Environment. Clear the browser's Java Cache.   OR   Cause: Computer and E-2D  
123) Document Type: General E-2D: Cannot login 0%
  [1682] Comments: 0, Last Modified: Feb 7, 2018 9:58 AM - Find Similar  
  E-2D: Cannot login Issue: Cannot login. Cause: Cannot remember password. Solution: Login as Administrator or “root” user to reset password. Cause: Cannot remember “root” password. OR Solution: Restore system default settings (WARNING: will erase ALL user configuration settings, including IP address and login information). Using a pen  
124) Document Type: General E-2D: ENVIROMUX will not recognize sensor 0%
  [1686] Comments: 0, Last Modified: Feb 7, 2018 9:56 AM - Find Similar  
  E-2D: ENVIROMUX will not recognize sensor Issue: ENVIROMUX will not recognize sensor. Cause: Previously used sensor port was not cleared from memory upon removal. Solution: Remove previous sensor data. Via the web interface, click on “???” in the summary page. Select “Configure,” then “Remove” at the bottom of the Configure page to remove  
125) Document Type: FAQ E-2D: How to Set Up Alerts and Different Contact Settings for Specific Times of the Day/Week 0%
  [1926] Comments: 0, Last Modified: Feb 7, 2018 10:18 AM - Find Similar  
  period. Set up two user accounts. If the available number of user accounts is an issue  
126) Document Type: General E-2D: LDAP user cannot login 0%
  [1681] Comments: 0, Last Modified: Feb 7, 2018 9:58 AM - Find Similar  
  E-2D: LDAP user cannot login Issue: LDAP user cannot login. Cause: Login username and/or password does not match in ENVIROMUX user list. Solution: Make sure the username and password in the LDAP server matches the ENVIROMUX user configuration. Check security configuration by selecting “Security” in the “Administration” section of the web interface menu. If security  
127) Document Type: General E-2D: Not receiving e-mail alert messages 0%
  [1687] Comments: 0, Last Modified: Feb 7, 2018 9:56 AM - Find Similar  
  E-2D: Not receiving e-mail alert messages Issue: Not receiving e-mail alert messages. Cause: Ethernet cable disconnected. Solution: Check Ethernet cable connections. OR Cause: Wrong or no IP address provided for SMTP server, or SSL enabled when it should not be selected. Solution ... , check event log and refer to email error codes below to resolve issue: Without SSL  
128) Document Type: General E-2D: Not receiving SMS text messages 0%
  [1683] Comments: 0, Last Modified: Feb 7, 2018 9:57 AM - Find Similar  
  E-2D: Not receiving SMS text messages Issue: Not receiving SMS text messages. Cause: SIM card is not configured or installed properly. Solution: Check the SIM card configuration, installation, and verify its IMEI number under “Enterprise Configuration.” Ensure that an unlocked GSM 3G SIM card is being used and that it supports SMS messages. OR Cause: Tower  
129) Document Type: General E-2D: Receive false alerts from the internal humidity sensor 0%
  [1702] Comments: 0, Last Modified: Feb 7, 2018 9:46 AM - Find Similar  
  E-2D: Receive false alerts from the internal humidity sensor Issue: Receive false alerts from the internal humidity sensor every 8 hours to 2 weeks. The alarm email is followed by returned to normal email. Cause: The Sample Period and Alert Delay settings are set too short in the sensor configuration. Solution: Set the Sample period to 10 seconds and the Alert Delay to 30 seconds for the humidity  
130) Document Type: General E-2D: Receive false alerts from the internal humidity sensor 0%
  [1706] Comments: 0, Last Modified: Feb 7, 2018 9:54 AM - Find Similar  
  E-2D: Receive false alerts from the internal humidity sensor Issue: Receive false alerts from the internal humidity sensor every 8 hours to 2 weeks. The alarm email is followed by returned to normal email. Cause: The Sample Period and Alert Delay settings are set too short in the sensor configuration. Solution: Set the Sample period to 10 seconds and the Alert Delay to 30 seconds for the humidity  
131) Document Type: General E-2D: Unable to Configure Frequency Sensor for E-ACLM-V/P 0%
  [2011] Comments: 0, Last Modified: Feb 7, 2018 9:54 AM - Find Similar  
  E-2D: Unable to Configure Frequency Sensor for E-ACLM-V/P Issue: Unable to configure frequency sensor for E-ACLM-V/P Cause: E-2D firmware has not been updated to version 2.29 or later. Solution: Update the firmware by downloading the latest version from http://www.networktechinc.com/download/d-environment-monitor-16.html and uploading via the Web Interface > Administration  
132) Document Type: General E-2D: Unable to Configure Frequency Sensor for ENVIROMUX-ACLM-V/P 0%
  [2012] Comments: 0, Last Modified: Feb 7, 2018 9:52 AM - Find Similar  
  E-2D: Unable to Configure Frequency Sensor for E-ACLM-V/P   Issue: Unable to configure frequency sensor for E-ACLM-V/P Cause: E-2D firmware has not been updated to version 2.29 or later. Solution: Update the firmware by downloading the latest version from http://www.networktechinc.com/download/d-environment-monitor-16.html and uploading via the Web Interface > Administration  
133) Document Type: General E-2D: Unable to connect via web interface / no login screen 0%
  [1679] Comments: 0, Last Modified: Feb 7, 2018 9:59 AM - Find Similar  
  E-2D: Unable to connect via web interface / no login screen Issue: Unable to connect via web interface / no login screen Cause: Wrong IP address. Solution: Use NTI Device Discovery Tool to locate configured IP address. Browse the installation manual CD and click on the file discover.html . This will open your browser and display the Device Discovery Tool page. Accept the Certificate  
134) Document Type: General E-2D: Unable to Send Out E-mail Alerts with IMAP or POP ports 0%
  [1689] Comments: 0, Last Modified: Feb 7, 2018 9:55 AM - Find Similar  
  E-2D: Unable to Send Out E-mail Alerts with IMAP or POP ports Issue: Unable to Send Out E-mail Alerts with IMAP or POP ports. Cause: E-2D does not use IMAP or POP ports. Solution: IMAP and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported, usually  
135) Document Type: General E-5D: "Pwr" LED is blinking 0%
  [1809] Comments: 0, Last Modified: Feb 7, 2018 11:10 AM - Find Similar  
  E-5D: “Pwr” LED is blinking Issue: “Pwr” LED is blinking. Cause: If LED is blinking 1/sec, main power is OFF and the battery backup is powering the ENVIROMUX. (This alarm can be verified on the summary screen of the web interface.) Solution: Restore AC power to the ENVIROMUX. OR Cause: If LED is blinking rapidly, Discovery Tool is currently in use and blink  