[1986]
Comments: 0,
Last Modified: Jan 31, 2018 10:52 AM
- Find Similar
, group, and notification settings, expand the Remote SSH Commands tab. Remote address ... also has some requirements for this setup to work. The computer needs to have an SSH server ... effect, restart the SSH server by typing: $ sudo service ssh restart
[1925]
Comments: 0,
Last Modified: Jan 31, 2018 10:55 AM
- Find Similar
E-16D: How to Turn Off Public SNMP SNMP public access is part of SNMP v1 and v2c. To disable these versions, take the following actions: On the web interface, go to Administration > Network > SNMP settings. Under “Enable SNMP Agent” select “SNMPv3” in the drop down menu and then select save on the bottom of the screen.
[1722]
Comments: 0,
Last Modified: Feb 8, 2024 5:51 PM
- Find Similar
an alarm if an intruder enters the enclosed room via other means. The set-up requires the operator ... timed delay and door strike set-up, the relay output of the keypad will be connected to the ENVIROMUX ... is typed again. This is key in settingup Smart Alerts so that an exception can be made while ... sensors. To set-up deactivation of the motion sensors while the operator is within the enclosed
[1598]
Comments: 0,
Last Modified: Jan 31, 2018 10:44 AM
- Find Similar
E-16D: Receive false alerts from the internal humidity sensor Issue: Receive false alerts from the internal humidity sensor every 8 hours to 2 weeks. The alarm email is followed by returned to normal email. Cause: The Sample Period and Alert Delay settings are set too short in the sensor configuration. Solution: Set the Sample period to 10 seconds and the Alert Delay to 30 seconds for the humidity
[2077]
Comments: 0,
Last Modified: Feb 13, 2024 11:53 AM
- Find Similar
can be found online. Enter the recipients’ email address in the E-1W web server under Administration > Users > Contact Settings > Email Address. Users will only receive the SMS ... . Then, select “Non-Critical Alert Settings” and/or “Critical Alert Settings&rdquo
[2054]
Comments: 0,
Last Modified: Feb 7, 2018 10:23 AM
- Find Similar
E-1W: Not Receiving Alert Messages Issue: Not receiving alert messages. Cause: Using E-mail that doesn't supports SSL encryption (like Gmail). Solution: When security is required, make sure the email server supports SSLv3 Authentication Protocol. OR Cause: E-mail does not support encryption, instead uses standard authentication. Solution: When using standard
[1682]
Comments: 0,
Last Modified: Feb 7, 2018 9:58 AM
- Find Similar
E-2D: Cannot login Issue: Cannot login. Cause: Cannot remember password. Solution: Login as Administrator or “root” user to reset password. Cause: Cannot remember “root” password. OR Solution: Restore system default settings (WARNING: will erase ALL user configuration settings, including IP address and login information). Using a pen
[2103]
Comments: 0,
Last Modified: Feb 7, 2018 10:01 AM
- Find Similar
E-2D: Does the Included Power Supply Adjust for Input Voltage? Yes. The power supply included with the E-2D is a switching power supply. It will automatically sense and adjust for input voltage, provided the voltage is within the acceptable range of 100 to 240 VAC at 50 or 60 Hz.
[2087]
Comments: 0,
Last Modified: Feb 7, 2018 10:02 AM
- Find Similar
E-2D: How Many E-MICRO Units can be Connected to an E-2D Master/Slave Cascade Configuration When configuring an advanced Master and Slave cascade, a maximum of eight E-MICRO IP Sensors can be connected to the configuration. This is because IP Sensor configuration can only be done through the E-2D Master unit, which allows for up to eight connected IP Sensors. NOTE: Sensors connected to the E