Use the form below to enter your search criteria. By default, all content is searched except for document comments. If you wish to search comments as well as everything else, click "Also Search Comments" below.
[2104]
Comments: 0,
Last Modified: Feb 7, 2018 11:11 AM
- Find Similar
E-5D: Does the Included Power Supply Adjust for Input Voltage? Yes. The power supply included with the E-5D is a switching power supply. It will automatically sense and adjust for input voltage, provided the voltage is within the acceptable range of 100 to 240 VAC at 50 or 60 Hz.
[2086]
Comments: 0,
Last Modified: Feb 7, 2018 11:12 AM
- Find Similar
E-5D: How Many E-MICRO Units can be Connected to an E-5D Master/Slave Cascade Configuration When configuring an advanced Master and Slave cascade, a maximum of eight E-MICRO IP Sensors can be connected to the configuration. This is because IP Sensor configuration can only be done through the E-5D Master unit, which allows for up to eight connected IP Sensors. NOTE: Sensors connected to the E
[2109]
Comments: 0,
Last Modified: Feb 7, 2018 11:11 AM
- Find Similar
E-5D: How To Preserve the Event and Data Logs When an E-5D loses power, internal memory (including Log Data) is lost. The E-5D Data Log can be set to preserve itself via automatic messaging under Log > Log Settings > Data Log Settings. To send log entries, enable Syslog, SNMP, and/or E ... Settings > Log To USB Flash Settings and select Enable Log to Flash drive. Logs will be automatically
[2075]
Comments: 0,
Last Modified: Feb 13, 2024 11:52 AM
- Find Similar
’ email address in the ENVIROMUX-5D web server under Administration > Users > Contact Settings > Email Address. When using SMS messages, “Brief email” can be enabled ... a sensor. Then, select “Non-Critical Alert Settings” and/or “Critical Alert Settings” > Enable Email Alerts.
[1987]
Comments: 0,
Last Modified: Feb 7, 2018 11:14 AM
- Find Similar
settings, expand the Remote SSH Commands tab. Remote address: Enter the IP address or host ... for this setup to work. The computer needs to have an SSH server installed and running. It needs ... , restart the SSH server by typing: $ sudo service ssh restart
[1924]
Comments: 0,
Last Modified: Feb 7, 2018 11:16 AM
- Find Similar
E-5D: How to Turn Off Public SNMP SNMP public access is part of SNMP v1 and v2c. To disable these versions, take the following actions: On the web interface, go to Administration > Network > SNMP settings. Under “Enable SNMP Agent” select “SNMPv3” in the drop down menu and then select save on the bottom of the screen.
[1723]
Comments: 0,
Last Modified: Feb 8, 2024 5:51 PM
- Find Similar
an alarm if an intruder enters the enclosed room via other means. The set-up requires the operator ... timed delay and door strike set-up, the relay output of the keypad will be connected to the ENVIROMUX ... until the code is typed again. This is key in settingup Smart Alerts so that an exception can be made ... area. With this setup, when an operator enters the code to access the room, both events
[1836]
Comments: 0,
Last Modified: Feb 7, 2018 11:06 AM
- Find Similar
E-5D: Receive false alerts from the internal humidity sensor Issue: Receive false alerts from the internal humidity sensor every 8 hours to 2 weeks. The alarm email is followed by returned to normal email. Cause: The Sample Period and Alert Delay settings are set too short in the sensor configuration. Solution: Set the Sample period to 10 seconds and the Alert Delay to 30 seconds for the humidity
[1832]
Comments: 0,
Last Modified: Feb 7, 2018 11:08 AM
- Find Similar
E-5D: Receive false alerts from the internal humidity sensor Issue: Receive false alerts from the internal humidity sensor every 8 hours to 2 weeks. The alarm email is followed by returned to normal email. Cause: The Sample Period and Alert Delay settings are set too short in the sensor configuration. Solution: Set the Sample period to 10 seconds and the Alert Delay to 30 seconds for the humidity
[174]
Comments: 0,
Last Modified: Feb 7, 2018 11:33 AM
- Find Similar
baud rate for the Aux port is set to 115200. Check the GSM Modem status message on the Enterprise Settings Screen (in the E-SEMS-16 Web Interface, click "Administration", then click "Settings", and "Enterprise"). GSM Modem Status Messages: GSM Modem ... ;GSM Phone #" field is correct in the Enterprise Settings Screen. GSM Modem Ready: Communication