Network Technologies Inc, Innovators in KVM SolutionsWelcome Return to NTI homepage
KVM
SWITCHES
CONSOLE
SWITCHES
KVM
SPLITTER
VIDEO
SWITCHES
VIDEO MATRIX
SWITCHES
VIDEO
SPLITTER
EXTENDERS
via CAT5
KVM
DRAWERS
MONITORS &
ACCESSORIES
SERVER
ENVIRONMENT
VIDEO
CONVERTERS
CABLES &
ADAPTERS


Knowledge Base Home » Knowledge Base Search

Knowledge Base Search

Use the form below to enter your search criteria. By default, all content is searched except for document comments. If you wish to search comments as well as everything else, click "Also Search Comments" below.

Enter Search Terms
Look For:
      [ Advanced Search | Tips ]
Welcome, Guest Help
Login Login
Click to change your viewing preferences Guest Settings


Search Results » 335 results for: SERIMUX console switch set up windows server 2003 Rank by:
Displaying results 46 - 60 Pages: [Previous | 1 2 3 4 5 6 7 ... 23 | Next ]
46) Document Type: FAQ E-MICRO: Can the E-MICRO ping traffic on a 10.x.x.x network and send emails to 153.x.x.x mail relay server 0%
  [2029] Comments: 0, Last Modified: Feb 7, 2018 10:37 AM - Find Similar  
  , special port forwarding needs to be set up on the network for switching from the "public" ... emails to 153.x.x.x mail relay server? Yes. If the E-MICRO is on the 10.x.x.x network, it can ping any device on the network and send emails to the 153.x.x.x mail server relay. A DSL type router wold work in this set up, but the E-MICRO would need a gateway set in the network settings that would allow  
47) Document Type: FAQ E-MINI-LXO: How to Use an LDAP Server with an E-MINI-LXO 0%
  [1975] Comments: 0, Last Modified: Feb 13, 2024 11:45 AM - Find Similar  
  port), you will be able to switch the security settings back to Local mode or make adjustments ... connection to break communication with the LDAP server. Connect to the ENVIROMUX through the Console ... E-MINI-LXO: How to Use an LDAP Server with an E-MINI-LXO Secure access to the web interface of the ENVIROMUX ... Protocol) server. Note: It is recommended that you establish a connection to the ENVIROMUX from  
48) Document Type: FAQ IPDU-Sx: How to Use an LDAP Server with an IPDU-Sx 0%
  [1979] Comments: 0, Last Modified: Feb 13, 2024 11:48 AM - Find Similar  
  an RS232 port or Console port), you will be able to switch the security settings back to Local ... IPDU-Sx: How to Use an LDAP Server with an IPDU-Sx Secure access to the web interface of the Secure ... Protocol) server. Note: It is recommended that you establish a connection to the IPDU-Sx from a second PC before changing these settings and logging out, because if a mistake is made in the configuration  
49) Document Type: General SERIMUX-CS-x: Cannot access user menu on a port. 0%
  [1620] Comments: 0, Last Modified: Nov 27, 2012 10:45 AM - Find Similar  
  SERIMUX-CS-x: Cannot access user menu on a port. Issue: Cannot access user menu on a port. Cause: Port is configured as host port. Solution: Configure user port with the following steps: Select “Port Configuration” and then “Port Settings.” Choose the desired port for configuration. Note: port must be disconnected in order to change settings. Under  
50) Document Type: General SERIMUX-CS-x: Cannot connect to port/device. 0%
  [1617] Comments: 0, Last Modified: Nov 27, 2012 10:41 AM - Find Similar  
  SERIMUX-CS-x: Cannot connect to port/device. Issue: Cannot connect to port/device. Cause: Port settings not correct. Solution: Verify proper communication settings. OR Cause: Wrong cable adapter used. Solution: Verify that adapter used is one of the following: DB-25 Male to RJ45 Pin Assignments. DB-9 Female to RJ45 Pin Assignments. DB-25 Female to RJ45 Pin Assignments  
51) Document Type: General SERIMUX-CS-x: Java SSH Applet Not Working 0%
  [1974] Comments: 0, Last Modified: Feb 13, 2024 11:45 AM - Find Similar  
  it with unsigned applets (jre-7u51-windows-i586.exe). Once installed, open the Java console to verify the installation. Go to Control Panel of your Windows program and double-click on Java. In the General ... SERIMUX-CS-x: Java SSH Applet Not Working Issue: Java SSH Applet not working. Cause: Java version ... the Java Console. Close your browser if it is still open, then re-open it. Enter the URL  
52) Document Type: General SERIMUX-CS-x: No front panel LEDs are illuminated 0%
  [1615] Comments: 0, Last Modified: Nov 27, 2012 10:40 AM - Find Similar  
  SERIMUX-CS-x: No front panel LEDs are illuminated. Issue: No front panel LEDs are illuminated. Cause: No power to SERIMUX unit. Solution: Check all power connections.  
53) Document Type: FAQ SERIMUX-S-x: Can SSH/Telnet be used raw with no password needed on a SERIMUX? 0%
  [1996] Comments: 0, Last Modified: Apr 20, 2015 2:48 PM - Find Similar  
  SERIMUX-S-x: Can SSH/Telnet be used raw with no password needed on a SERIMUX? Yes, SSH/Telnet can be used raw with no password required. This can be done by disabling authentication for a port under Port Management. Normal 0 false false false EN-US ZH-CN X-NONE /* Style  
54) Document Type: General SERIMUX-S-x: Cannot connect to port/device. 0%
  [1612] Comments: 0, Last Modified: Nov 27, 2012 10:38 AM - Find Similar  
  SERIMUX-S-x: Cannot connect to port/device. Issue: Cannot connect to port/device. Cause: Port settings not correct. Solution: Verify proper communication settings. OR Cause: Wrong cable adapter used. Solution: Verify that adapter used is one of the following: DB-25 Male to RJ45 Pin Assignments. DB-9 Female to RJ45 Pin Assignments. DB-25 Female to RJ45 Pin Assignments  
55) Document Type: FAQ SERIMUX-S-x: Is it possible to connect directly to a port via SSH on the SERIMUX-S-x? 0%
  [1997] Comments: 0, Last Modified: Apr 20, 2015 2:49 PM - Find Similar  
  SERIMUX-S-x: Is it possible to connect directly to a port via SSH on the SERIMUX-S-x? Yes, it is possible to connect directly to a port via SSH. Example: root 7026 10.7.87.92 "root" is the user "7026" is the port number "10.7.87.92" is the IP address for the console switch. Normal 0 false false false  
56) Document Type: General SERIMUX-S-x: Java SSH Applet Not Working 0%
  [1973] Comments: 0, Last Modified: Feb 8, 2024 5:01 PM - Find Similar  
  that will enable you to use it with unsigned applets (jre-7u51-windows-i586.exe). Once installed, open the Java console to verify the installation. Go to Control Panel of your Windows program and double ... -font:minor-bidi;} SERIMUX-S-x: Java SSH Applet Not Working Issue: Java SSH Applet not working ... ;OK" to close the Java Console. Close your browser if it is still open, then re-open it. Enter  
57) Document Type: General SERIMUX-S-x: No front panel LEDs are illuminated. 0%
  [1610] Comments: 0, Last Modified: Nov 27, 2012 10:35 AM - Find Similar  
  SERIMUX-S-x: No front panel LEDs are illuminated. Issue: No front panel LEDs are illuminated. Cause: No power to SERIMUX unit. Solution: Check all power connections.  
58) Document Type: General ST-C5KVM-600 KVM Extenders via CAT5: Doesn?t work properly or at all when on UPS backup power. 0%
  [152] Comments: 0, Last Modified: Feb 6, 2009 3:11 PM - Find Similar  
  Issue: The ST-C5KVM-600 KVM Extender doesn?t work properly or at all when on UPS backup power. Cause: Backup power from most UPS power supplies is not compatible with unregulated wall transformer power adapter. Solution: Replace the unregulated 9V/1.5A wall transformer power adapter with the 9V/1.5A regulated switching power supply PS4074.  
59) Document Type: General ST-C5USBV: The USB keyboard and mouse do not respond after Windows resumes from sleep, hibernation or computer 0%
  [117] Comments: 0, Last Modified: Feb 6, 2009 3:16 PM - Find Similar  
  Issue: The USB keyboard and mouse do not respond after Windows resumes from sleep, hibernation or computer inactivity. Cause: Windows puts the USB Root Hub into a conserve power mode, which causes the XTENDEX USB KVM Extender (ST-C5USBV, ST-C5USBV-300) to lose the USB connection with the computer. Solution: Turn off Windows? ability to turn off the USB Root Hub by going to: Power Management Uncheck  
60) Document Type: General ST-C5V-600 VGA Extenders via CAT5: Doesn?t work properly or at all when on UPS backup power. 0%
  [153] Comments: 0, Last Modified: Feb 6, 2009 3:18 PM - Find Similar  
  Issue: The ST-C5V-600 VGA Extender doesn?t work properly or at all when on UPS backup power. Cause: Backup power from most UPS power supplies is not compatible with unregulated wall transformer power adapter. Solution: Replace the unregulated 9V/1.5A wall transformer power adapter with the 9V/1.5A regulated switching power supply PS4074.  


335 results for: SERIMUX console switch set up windows server 2003, Displaying results 46 - 60 Pages: [Previous | 1 2 3 4 5 6 7 ... 23 | Next ]