- Find Similar
, special port forwarding needs to be setup on the network for switching from the "public" ... emails to 153.x.x.x mail relay server? Yes. If the E-MICRO is on the 10.x.x.x network, it can ping any device on the network and send emails to the 153.x.x.x mail server relay. A DSL type router wold work in this setup, but the E-MICRO would need a gateway set in the network settings that would allow
[1975]
Comments: 0,
Last Modified: Feb 13, 2024 11:45 AM
- Find Similar
port), you will be able to switch the security settings back to Local mode or make adjustments ... connection to break communication with the LDAP server. Connect to the ENVIROMUX through the Console ... E-MINI-LXO: How to Use an LDAP Server with an E-MINI-LXO Secure access to the web interface of the ENVIROMUX ... Protocol) server. Note: It is recommended that you establish a connection to the ENVIROMUX from
[1979]
Comments: 0,
Last Modified: Feb 13, 2024 11:48 AM
- Find Similar
an RS232 port or Console port), you will be able to switch the security settings back to Local ... IPDU-Sx: How to Use an LDAP Server with an IPDU-Sx Secure access to the web interface of the Secure ... Protocol) server. Note: It is recommended that you establish a connection to the IPDU-Sx from a second PC before changing these settings and logging out, because if a mistake is made in the configuration
[1620]
Comments: 0,
Last Modified: Nov 27, 2012 10:45 AM
- Find Similar
SERIMUX-CS-x: Cannot access user menu on a port. Issue: Cannot access user menu on a port. Cause: Port is configured as host port. Solution: Configure user port with the following steps: Select “Port Configuration” and then “Port Settings.” Choose the desired port for configuration. Note: port must be disconnected in order to change settings. Under
[1617]
Comments: 0,
Last Modified: Nov 27, 2012 10:41 AM
- Find Similar
SERIMUX-CS-x: Cannot connect to port/device. Issue: Cannot connect to port/device. Cause: Port settings not correct. Solution: Verify proper communication settings. OR Cause: Wrong cable adapter used. Solution: Verify that adapter used is one of the following: DB-25 Male to RJ45 Pin Assignments. DB-9 Female to RJ45 Pin Assignments. DB-25 Female to RJ45 Pin Assignments
[1974]
Comments: 0,
Last Modified: Feb 13, 2024 11:45 AM
- Find Similar
it with unsigned applets (jre-7u51-windows-i586.exe). Once installed, open the Java console to verify the installation. Go to Control Panel of your Windows program and double-click on Java. In the General ... SERIMUX-CS-x: Java SSH Applet Not Working Issue: Java SSH Applet not working. Cause: Java version ... the Java Console. Close your browser if it is still open, then re-open it. Enter the URL
[1615]
Comments: 0,
Last Modified: Nov 27, 2012 10:40 AM
- Find Similar
SERIMUX-CS-x: No front panel LEDs are illuminated. Issue: No front panel LEDs are illuminated. Cause: No power to SERIMUX unit. Solution: Check all power connections.
[1996]
Comments: 0,
Last Modified: Apr 20, 2015 2:48 PM
- Find Similar
SERIMUX-S-x: Can SSH/Telnet be used raw with no password needed on a SERIMUX? Yes, SSH/Telnet can be used raw with no password required. This can be done by disabling authentication for a port under Port Management. Normal 0 false false false EN-US ZH-CN X-NONE /* Style
[1612]
Comments: 0,
Last Modified: Nov 27, 2012 10:38 AM
- Find Similar
SERIMUX-S-x: Cannot connect to port/device. Issue: Cannot connect to port/device. Cause: Port settings not correct. Solution: Verify proper communication settings. OR Cause: Wrong cable adapter used. Solution: Verify that adapter used is one of the following: DB-25 Male to RJ45 Pin Assignments. DB-9 Female to RJ45 Pin Assignments. DB-25 Female to RJ45 Pin Assignments
[1997]
Comments: 0,
Last Modified: Apr 20, 2015 2:49 PM
- Find Similar
SERIMUX-S-x: Is it possible to connect directly to a port via SSH on the SERIMUX-S-x? Yes, it is possible to connect directly to a port via SSH. Example: root 7026 10.7.87.92 "root" is the user "7026" is the port number "10.7.87.92" is the IP address for the consoleswitch. Normal 0 false false false
[1973]
Comments: 0,
Last Modified: Feb 8, 2024 5:01 PM
- Find Similar
that will enable you to use it with unsigned applets (jre-7u51-windows-i586.exe). Once installed, open the Java console to verify the installation. Go to Control Panel of your Windows program and double ... -font:minor-bidi;} SERIMUX-S-x: Java SSH Applet Not Working Issue: Java SSH Applet not working ... ;OK" to close the Java Console. Close your browser if it is still open, then re-open it. Enter
[1610]
Comments: 0,
Last Modified: Nov 27, 2012 10:35 AM
- Find Similar
SERIMUX-S-x: No front panel LEDs are illuminated. Issue: No front panel LEDs are illuminated. Cause: No power to SERIMUX unit. Solution: Check all power connections.
[152]
Comments: 0,
Last Modified: Feb 6, 2009 3:11 PM
- Find Similar
Issue: The ST-C5KVM-600 KVM Extender doesn?t work properly or at all when on UPS backup power. Cause: Backup power from most UPS power supplies is not compatible with unregulated wall transformer power adapter. Solution: Replace the unregulated 9V/1.5A wall transformer power adapter with the 9V/1.5A regulated switching power supply PS4074.
[117]
Comments: 0,
Last Modified: Feb 6, 2009 3:16 PM
- Find Similar
Issue: The USB keyboard and mouse do not respond after Windows resumes from sleep, hibernation or computer inactivity. Cause: Windows puts the USB Root Hub into a conserve power mode, which causes the XTENDEX USB KVM Extender (ST-C5USBV, ST-C5USBV-300) to lose the USB connection with the computer. Solution: Turn off Windows? ability to turn off the USB Root Hub by going to: Power Management Uncheck
[153]
Comments: 0,
Last Modified: Feb 6, 2009 3:18 PM
- Find Similar
Issue: The ST-C5V-600 VGA Extender doesn?t work properly or at all when on UPS backup power. Cause: Backup power from most UPS power supplies is not compatible with unregulated wall transformer power adapter. Solution: Replace the unregulated 9V/1.5A wall transformer power adapter with the 9V/1.5A regulated switching power supply PS4074.
335 results for:
SERIMUX console switch set up windows server 2003,
Displaying results 46 - 60