Network Technologies Inc, Innovators in KVM SolutionsWelcome Return to NTI homepage
KVM
SWITCHES
CONSOLE
SWITCHES
KVM
SPLITTER
VIDEO
SWITCHES
VIDEO MATRIX
SWITCHES
VIDEO
SPLITTER
EXTENDERS
via CAT5
KVM
DRAWERS
MONITORS &
ACCESSORIES
SERVER
ENVIRONMENT
VIDEO
CONVERTERS
CABLES &
ADAPTERS


Knowledge Base Home » Knowledge Base Search

Knowledge Base Search

Use the form below to enter your search criteria. By default, all content is searched except for document comments. If you wish to search comments as well as everything else, click "Also Search Comments" below.

Enter Search Terms
Look For:
      [ Advanced Search | Tips ]
Welcome, Guest Help
Login Login
Click to change your viewing preferences Guest Settings


Search Results » 335 results for: SERIMUX console switch set up windows server 2003 Rank by:
Displaying results 91 - 105 Pages: [Previous | 1 ... 4 5 6 7 8 9 10 ... 23 | Next ]
91) Document Type: FAQ UNIMUX-nXm-UHD: How to Receive Switching Notifications via RS232 or Ethernet 0%
  [1939] Comments: 0, Last Modified: Jun 21, 2013 9:23 AM - Find Similar  
  ;SS SW,01”, where SW is the unit address of the switch. Up to 15 units can be daisy-chained and controlled by RS232. If switch 01 is to activate Autostatus, the following should be entered: SS 01,01 If switch 05 is to activate Autostatus, the following should be entered: SS 05,01 ... UNIMUX-nXm-UHD: How to Receive Switching Notifications via RS232 or Ethernet Using RS232 or Telnet  
92) Document Type: FAQ What is the default IP address for NTI?s VEEMUX Video and Audio/Video Matrix Switches? 0%
  [61] Comments: 0, Last Modified: Feb 6, 2009 3:26 PM - Find Similar  
  What is the default IP address for NTI?s VEEMUX Video and Audio/Video Matrix Switches? When trying to access the browser interface on a video or audio/video matrix switch, the default IP address is needed to log into the switch screen. For SM-nXm-15V-LCD, SM-nXm-AV-LCD and SM-8x4-HDA video matrix switch models, the default IP addess is 192.168.1.30 For SM-nXm-C5AV-LCD video matrix switch model, the default  
93) Document Type: FAQ What is the ideal temperature and humidity for my server room? 0%
  [198] Comments: 0, Last Modified: Jan 3, 2011 3:54 PM - Find Similar  
  What is the ideal temperature and humidity for my server room? The generally accepted, ideal temperature is between 68 and 74 degrees Fahrenheit (20 to 24 degrees Celsius). When the temperature is between 68 and 74 degrees Fahrenheit (20 to 24 degrees Celsius), the relative humidity should be between 40% and 50%.  
94) Document Type: General E-16D: Cannot access ENVIROMUX through my browser 0%
  [1576] Comments: 0, Last Modified: Jan 31, 2018 10:47 AM - Find Similar  
  IP address to resolve conflict. Log into unit via USB console. Under “Network Settings ... mask, or other network related restrictions. OR Cause: Just set up DHCP and not connected to a DHCP switch. Solution: Reconfigure the unit to static IP or verify the DHCP server and addresses  
95) Document Type: General E-16D: Unable to Send Out E-mail Alerts with IMAP or POP ports 0%
  [1608] Comments: 0, Last Modified: Jan 31, 2018 10:43 AM - Find Similar  
  and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported, usually corresponding ... as necessary. Only fill in username and password if required for SMTP server.  
96) Document Type: General E-2D: Cannot access ENVIROMUX through my browser 0%
  [1685] Comments: 0, Last Modified: Feb 7, 2018 9:57 AM - Find Similar  
  restrictions. OR Cause: Just set up DHCP and not connected to a DHCP switch. Solution: Reconfigure the unit to static IP or verify the DHCP server and addresses available. ... . Log into unit via USB console. Under “Network Settings,” change the IP  
97) Document Type: General E-2D: Unable to Send Out E-mail Alerts with IMAP or POP ports 0%
  [1689] Comments: 0, Last Modified: Feb 7, 2018 9:55 AM - Find Similar  
  and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported, usually ... or disabled as necessary. Only fill in username and password if required for SMTP server.  
98) Document Type: General E-5D: Cannot access ENVIROMUX through my browser 0%
  [1810] Comments: 0, Last Modified: Feb 7, 2018 11:10 AM - Find Similar  
  restrictions. OR Cause: Just set up DHCP and not connected to a DHCP switch. Solution: Reconfigure the unit to static IP or verify the DHCP server and addresses available. ... . Log into unit via USB console. Under “Network Settings,” change the IP  
99) Document Type: General E-5D: Unable to Send Out E-mail Alerts with IMAP or POP ports 0%
  [1821] Comments: 0, Last Modified: Feb 7, 2018 11:08 AM - Find Similar  
  and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported, usually ... or disabled as necessary. Only fill in username and password if required for SMTP server.  
100) Document Type: FAQ E-MICRO: Can I adapt communications between the E-MICRO and a Gigabit network switch? 0%
  [2030] Comments: 0, Last Modified: Feb 7, 2018 10:37 AM - Find Similar  
  the E-MICRO and a Gigabit network switch? Yes. Most Gigabit switches are 10/100/1000 compatible  
101) Document Type: General E-MINI-LXO: Unable to Send Out E-mail Alerts with IMAP or POP ports 0%
  [1607] Comments: 0, Last Modified: Feb 7, 2018 10:43 AM - Find Similar  
  : IMAP and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported, usually ... or disabled as necessary. Only fill in username and password if required for SMTP server  
102) Document Type: General E-SEMS-16: Unable to Send Out E-mail Alerts with IMAP or POP ports 0%
  [1609] Comments: 0, Last Modified: Feb 7, 2018 11:34 AM - Find Similar  
  : IMAP and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported ... server.  
103) Document Type: General V240 server with XVR-100 graphics card 0%
  [115] Comments: 0, Last Modified: Feb 6, 2009 3:20 PM - Find Similar  
  Issue: RACKMUX-US17 defaults to 1152x870 screen resolution (instead of its maximum 1280x1024 resolution) after reboot when used with a Sun Fire V240 server with XVR-100 graphics card Cause: The Sun Fire V240 server automatically performs the DDC test to detect the monitor?s default resolution, in this case 1152x870, and starts the graphics session with that resolution. Solution: Change the default  
104) Document Type: FAQ SPLITMUX-DVI-4RT: How to Control Multiple PCs on a Split Screen with One Keyboard/Mouse 0%
  [1969] Comments: 0, Last Modified: Mar 17, 2014 3:25 PM - Find Similar  
  . Use arrow keys to navigate to the CONSOLE menu and the entry MOUSE, then press ENTER/SELECT to open the MOUSE window. To quickly switch control between the multiple screens of various PCs in a split screen environment using one monitor and one set of keyboard and mouse, apply a checkmark in the box "Enable cross channel switching." Once this feature is enabled, simply move the mouse  
105) Document Type: FAQ SPLITMUX-HD-4RT: How to Configure and Access Slave Units in a Cascade Setup 0%
  [1999] Comments: 0, Last Modified: Feb 13, 2024 11:49 AM - Find Similar  
  , all slave display windows will be shown as dotted lines. Simply double click on the corresponding slave display window to access a slave unit's settings and configure any changes in display settings ... using the Cascade Settings page on the Web Interface and entering the IP address of each cascaded ... slave unit (IP 3). To go back to a unit that is higher up in the hierarchy, click on the corresponding  