  • E-SEMS-16 in: ENVIROMUX - Server Environment Monitoring

Search Results » 6 results for: ENVIROMUX-SEMS-16 Rank by:
Displaying results 1 - 6
1) Document Type: General E-SEMS-16: All front panel LEDs are on, unit is unresponsive 100%
  [195] Comments: 0, Last Modified: Feb 7, 2018 11:33 AM - Find Similar  
  of the E-SEMS-x Unit (default is 9600). 2. Turn the ENVIROMUX-SEMS-16 off, and then back on. (If the ENVIROMUX-SEMS-16 is still on after the power switch is turned off, press the "Reset ... upgrade. 4. Once the upgrade is complete, the E-SEMS-16 should reboot with the new firmware ... . Solution: 1. Connect a serial cable between a PC and the console port of the E-SEMS  
2) Document Type: General E-SEMS-16: How do I recover the root password? 42%
  [194] Comments: 0, Last Modified: Feb 7, 2018 11:33 AM - Find Similar  
  How do I access/recover the root password of an E-SEMS-x? Steps to Access the Root Password of an E-SEMS-x Unit: 1. Connect a serial cable between a PC and the console port of the E-SEMS-x Unit. Have ... -SEMS-x Unit (default is 9600). To test the connection, hit "enter" and a message requesting ... to detect the E-SEMS-x in the network. This requires that the PC where the Discover tool is ran and the E  
3) Document Type: FAQ E-SEMS-16: Why are my combination temperature/humidity sensors reading different humidity values? 24%
  [197] Comments: 0, Last Modified: Feb 8, 2024 5:46 PM - Find Similar  
  Why are my combination temperature/humidity sensors reading different humidity values? If you have two or more sensors reading different humidity values, the most likely cause is that the ...  
4) Document Type: FAQ What is the ideal temperature and humidity for my server room? 24%
  [198] Comments: 0, Last Modified: Jan 3, 2011 3:54 PM - Find Similar  
  What is the ideal temperature and humidity for my server room? The generally accepted, ideal temperature is between 68 and 74 degrees Fahrenheit (20 to 24 degrees Celsius). When the temperature is ...  
5) Document Type: FAQ E-SEMS-16: How can I tell if my smoke detection sensor is working? 3%
  [133] Comments: 1, Last Modified: Feb 7, 2018 11:27 AM - Find Similar  
  : The sensor's LEDs should be on ?Red? continuously. If the sensor is used on the ENVIROMUX-SEMS-16 with an alarm beacon, the alarm should sound after the alert delay time you set has elapsed. To reset the sensor, unplug it and plug it back in. Also, ackowledge the alert on the ENVIROMUX-SEMS-16 or the E-MINI from the testing the sensor in order to receive future alerts. Is there a way  
6) Document Type: General E-SEMS-16: Unable to Send Out E-mail Alerts with IMAP or POP ports 3%
  [1609] Comments: 0, Last Modified: Feb 7, 2018 11:34 AM - Find Similar  
  E-SEMS-16: Unable to Send Out E-mail Alerts with IMAP or POP ports Issue: Unable to Send Out E-mail Alerts with IMAP or POP ports. Cause: ENVIROMUX-SEMS-16 does not use IMAP or POP ports. Solution: IMAP and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported  


6 results for: ENVIROMUX-SEMS-16, Displaying results 1 - 6