- Find Similar
of the E-SEMS-x Unit (default is 9600). 2. Turn the ENVIROMUX-SEMS-16 off, and then back on. (If the ENVIROMUX-SEMS-16 is still on after the power switch is turned off, press the "Reset ... upgrade. 4. Once the upgrade is complete, the E-SEMS-16 should reboot with the new firmware ... . Solution: 1. Connect a serial cable between a PC and the console port of the E-SEMS
[194]
Comments: 0,
Last Modified: Feb 7, 2018 11:33 AM
- Find Similar
How do I access/recover the root password of an E-SEMS-x? Steps to Access the Root Password of an E-SEMS-x Unit: 1. Connect a serial cable between a PC and the console port of the E-SEMS-x Unit. Have ... -SEMS-x Unit (default is 9600). To test the connection, hit "enter" and a message requesting ... to detect the E-SEMS-x in the network. This requires that the PC where the Discover tool is ran and the E
[197]
Comments: 0,
Last Modified: Feb 8, 2024 5:46 PM
- Find Similar
Why are my combination temperature/humidity sensors reading different humidity values? If you have two or more sensors reading different humidity values, the most likely cause is that the ...
[198]
Comments: 0,
Last Modified: Jan 3, 2011 3:54 PM
- Find Similar
What is the ideal temperature and humidity for my server room? The generally accepted, ideal temperature is between 68 and 74 degrees Fahrenheit (20 to 24 degrees Celsius). When the temperature is ...
[133]
Comments: 1,
Last Modified: Feb 7, 2018 11:27 AM
- Find Similar
: The sensor's LEDs should be on ?Red? continuously. If the sensor is used on the ENVIROMUX-SEMS-16 with an alarm beacon, the alarm should sound after the alert delay time you set has elapsed. To reset the sensor, unplug it and plug it back in. Also, ackowledge the alert on the ENVIROMUX-SEMS-16 or the E-MINI from the testing the sensor in order to receive future alerts. Is there a way
[1609]
Comments: 0,
Last Modified: Feb 7, 2018 11:34 AM
- Find Similar
E-SEMS-16: Unable to Send Out E-mail Alerts with IMAP or POP ports Issue: Unable to Send Out E-mail Alerts with IMAP or POP ports. Cause: ENVIROMUX-SEMS-16 does not use IMAP or POP ports. Solution: IMAP and POP ports are only for receiving email. To enable outgoing email alerts, set up SMTP server and ensure the following: Correct IP address for SMTP server. SMTP port is supported