Why are my combination temperature/humidity sensors reading different humidity values? If you have two or more sensors reading different humidity values, the most likely cause is that the temperature values are different for each sensor. When air gets warmer, more water can be “held” in the air, and when the air gets colder, less water can be “held”. This relationship is known
[198]
Comments: 0,
Last Modified: Jan 3, 2011 3:54 PM
- Find Similar
What is the ideal temperature and humidity for my server room? The generally accepted, ideal temperature is between 68 and 74 degrees Fahrenheit (20 to 24 degrees Celsius). When the temperature is ...
[1818]
Comments: 0,
Last Modified: Feb 7, 2018 11:08 AM
- Find Similar
E-5 D: Sensors connected to RJ45 sensor ports stop working Issue: Sensors connected to RJ45 sensor ports stop working. Cause: Sensors applied collectively exceed current rating of row (ports 1-5). Fuse protecting ports has opened. Solution: Disconnect sensors. Power cycle the unit. Reconnect the sensors, ensuring that the load of all 5 sensors per row does not exceed 500mA (i.e. only
[1584]
Comments: 0,
Last Modified: Jan 31, 2018 10:45 AM
- Find Similar
E-16D: Sensors connected to RJ45 sensor ports stop working Issue: Sensors connected to RJ45 sensor ports stop working. Cause: Sensors applied collectively exceed current rating of row (row 1 = ports 1-8; row 2 = ports 9-16). Fuse protecting ports has opened. Solution: Disconnect sensors. Power cycle the unit. Reconnect the sensors, ensuring that the load of all 8 sensors per row does
[1578]
Comments: 0,
Last Modified: Jan 31, 2018 10:46 AM
- Find Similar
E-16D: ENVIROMUX will not recognize sensor Issue: ENVIROMUX will not recognize sensor. Cause: Previously used sensor port was not cleared from memory upon removal. Solution: Remove previous sensor data. Via the web interface, click on “???” in the summary page. Select ... and clear the port. If this does not work, call customer support (broken unit/sensor).
[1686]
Comments: 0,
Last Modified: Feb 7, 2018 9:56 AM
- Find Similar
E-2D: ENVIROMUX will not recognize sensor Issue: ENVIROMUX will not recognize sensor. Cause: Previously used sensor port was not cleared from memory upon removal. Solution: Remove previous sensor data. Via the web interface, click on “???” in the summary page. Select ... and clear the port. If this does not work, call customer support (broken unit/sensor).
[1812]
Comments: 0,
Last Modified: Feb 7, 2018 11:09 AM
- Find Similar
E-5D: ENVIROMUX will not recognize sensor Issue: ENVIROMUX will not recognize sensor. Cause: Previously used sensor port was not cleared from memory upon removal. Solution: Remove previous sensor data. Via the web interface, click on “???” in the summary page. Select ... and clear the port. If this does not work, call customer support (broken unit/sensor).
[23]
Comments: 0,
Last Modified: Feb 7, 2018 10:55 AM
- Find Similar
Issue: Sensor summary page fails to list sensors Cause: Browser is incorrectly going to the cache for updates. Observed in both Netscape and Firefox browsers (all versions) Solution: Clear the browser cache and reload the page OR Disable caching within the browser OR Use Internet Explorer 6.0 or higher for web configuration
[31]
Comments: 0,
Last Modified: Feb 7, 2018 10:56 AM
- Find Similar
How many sensors can the E-MINI use? The E-MINI can support up to 7 sensors at a time; 2 cat5 sensors, 4 dry contact sensors, and 1 water sensor. The temperature/humidity combination sensors act as 2 sensors in one, in effect allowing up to 9 sensors if combination sensors are used in the cat5 ports.
[1594]
Comments: 0,
Last Modified: Jan 31, 2018 11:04 AM
- Find Similar
E-16D: The sensor graphs do not appear in the web interface after installing the sensors. Ensure that you have Java Runtime Environment version 1.5 or newer installed on your computer and are using a compatible browser. Java Runtime Environment can be downloaded from: http://www.java.com/en/download/manual.jsp Download and install Java Runtime Environment. Clear the browser
[1697]
Comments: 0,
Last Modified: Feb 7, 2018 10:16 AM
- Find Similar
E-2D: The sensor graphs do not appear in the web interface after installing the sensors. Ensure that you have Java Runtime Environment version 1.5 or newer installed on your computer and are using a compatible browser. Java Runtime Environment can be downloaded from: http://www.java.com/en/download/manual.jsp Download and install Java Runtime Environment. Clear the browser
[1829]
Comments: 0,
Last Modified: Feb 7, 2018 11:18 AM
- Find Similar
E-5D: The sensor graphs do not appear in the web interface after installing the sensors. Ensure that you have Java Runtime Environment version 1.5 or newer installed on your computer and are using a compatible browser. Java Runtime Environment can be downloaded from: http://www.java.com/en/download/manual.jsp Download and install Java Runtime Environment. Clear the browser
[1589]
Comments: 0,
Last Modified: Nov 6, 2012 9:26 AM
- Find Similar
ENVIROMUX-16D: The sensor graphs do not appear in the web interface after installing the sensors. Ensure that you have Java Runtime Environment version 1.5 or newer installed on your computer and are using a compatible browser. Java Runtime Environment can be downloaded from: http://www.java.com/en/download/manual.jsp Download and install Java Runtime Environment. Clear the browser
[1701]
Comments: 0,
Last Modified: Jan 7, 2013 3:21 PM
- Find Similar
ENVIROMUX-2D: The sensor graphs do not appear in the web interface after installing the sensors. Ensure that you have Java Runtime Environment version 1.5 or newer installed on your computer and are using a compatible browser. Java Runtime Environment can be downloaded from: http://www.java.com/en/download/manual.jsp Download and install Java Runtime Environment. Clear the browser