Temperature Sensor |
Humidity Sensor |

ENVIROMUX-STS $50  |
 |
|
- Applications from 32°F to 122°F
(0°C to 50°C).
- Accurate to within ±2°F (±1°C).
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 1,000 ft. (not included).
- Regulatory approvals: RoHS
- Compatible with ENVIROMUX-SEMS-16 only.
|

ENVIROMUX-SHS $70  |
 |
|
- Applications from 20% to 80% relative humidity at temperatures between
32°F and 104°F (0°C to 40°C).
- Accurate to within ±5% relative humidity.
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 1,000 ft. (not included)
- Regulatory approvals: RoHS
- Compatible with ENVIROMUX-SEMS-16 only.
|
Temperature/Humidity Sensor |
Temperature/Wide Range Humidity Sensor |

|
- Applications from 32°F to 122°F
(0°C to 50°C) and 20% to 80% relative humidity.
- Accurate to within ±2°F (±1°C) and ±5% relative humidity.
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 1,000 ft.(not included)
- Regulatory approvals: RoHS
- Compatible with ENVIROMUX-SEMS-16 only.
|

|
- Applications from 32°F to 122°F
- Accurate to within ±2°F
(0°C to 50°C, ±1°C)
- 20% to 80% relative humidity, ±3%
- 10% to 90% relative humidity, ±4%
- 0% to 99% relative humidity, ±5%
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 1,000 ft.(not included)
- Regulatory approvals: RoHS
- Compatible with ENVIROMUX-SEMS-16 only.
|
Precision Humidity Sensor |
Precision Temperature/Humidity Sensor |

ENVIROMUX-SHS-PLT $548  |
|
|
- NIST certified accurate to within ±1% from 10% to 80% relative humidity at 77°F to 95°F (25°C to 35°C).
- Two-point field calibration.
- Output: 4-20mA DC = 0% to 100% RH.
- Requires the ENVIROMUX-S420MA to operate.
|

|
- Available temperature ranges:
- ENVIROMUX-STHS-PLT-120:
20°F to 120°F (-6°C to 48°C).
- ENVIROMUX-STHS-PLT-140:
-20°F to 140°F (-28°C to 60°C).
- ENVIROMUX-STHS-PLT-180:
30°F to 180°F (-1°C to 82°C).
- Temperature accurate to within ± 1.50%.
- NIST certified accurate to within ±1% from 10% to 80% relative humidity at 77°F to 95°F (25°C to 35°C).
- Uses a platinum RTD for precision temperature compensation.
- Sensing element: 1000W platinum; 2 lead resistance thermometer, .00385 TCR.
- Two-point field calibration.
- Output: 4-20mA DC = 0% to 100% RH.
- Requires the ENVIROMUX-S420MA to operate.
|
| Part # |
Price $ |
| ENVIROMUX-STHS-PLT-120 |
$752 |
 |
| ENVIROMUX-STHS-PLT-140 |
$752 |
 |
| ENVIROMUX-STHS-PLT-180 |
$752 |
 | |
|
|
Liquid Detection Sensor |
Smoke Detection Sensor |

|
- For warning of flooding.
- Detects liquid depth >0.1".
- Minimum puddle: 0.6" diameter.
- 100% waterproof electronics.
- Detects any liquid, except deionized water.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 1,000 ft. (not included)
- Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet.
- Available 2-wire cable (y) lengths: 5/10/20/50/100 feet.
- Regulatory approvals: CE, RoHS
- Requires the ENVIROMUX-SEMS-16 to operate
|
 ENVIROMUX-SDS $122 
Knowledge Base |
- For warning of smoke.
- Built-in 135° F (57° C) thermal heat sensor.
- Includes mounting hardware.
- Connect to RJ45 or digital input sensor ports.
- Supports CAT5/5e/6 UTP or STP cables.
- Photoelectric smoke detector.
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Maximum cable length: 1,000 ft
- Regulatory approvals: UL
|
Air Flow Sensor |
Carbon Monoxide Detector |

|
- Reliable mechanical solution for monitoring
air flow.
- Reacts to any condition causing insufficient flow of air such as malfunctioning cooling fan, increased friction, or physical blockage.
- Can be used for direct monitoring of a cooling fan.
- Dimensions WxDxH (in): 1.34x.7x.3
- Switch contact is closed when air flow
is >8.2 ft/s.
- Connection: 2x single strand AWG26,
length 18 in.
- Regulatory approvals: RoHS
|

ENVIROMUX-CMD $180 
|
|
- Continuous air monitoring.
- Pre-set alarm points alert at:
- 70 ppm after 60 to 240 minutes
- 150 ppm after 10 to 50 minutes
- 400 ppm after 4 to 15 minutes
- Flush or surface mount.
- LED indicators for operation status and system test.
|
Air Velocity Sensor |
Sensor Cables |

|
- Reliable sensor for measurement of air velocity.
- Air velocity sensor requires converter unit ENVIROMUX-AV-SB2
- Connect up to two air velocity sensors.
- Includes mounting hardware.
- Locate up to 1,000 ft from the ENVIROMUX-SEMS-16 via CAT5/5e/6 cable(not included).
- Connectors:
- Two RJ11 connectors for air velocity sensor
- RJ45 connector for ENVIROMUX-SEMS-16.
- Flow range: 0-3m/s +/-10% accuracy at 77°F (25°C) 1 atmosphere.
- Dust resistant design.
- Sensor cable available in lengths: 3, 7, 10, 25, 50, and 100 feet.
- Regulatory approvals: RoHS.
- Requires the ENVIROMUX-SEMS-16 to operate.
|

ENVIROMUX-2W-xx
| Length (ft) |
Price $ |
| 3 |
$1.50 |
 |
| 6 |
$3 |
 |
| 10 |
$5 |
 |
| 25 |
$12.50 |
 |
| 50 |
$25 |
 |
| 100 |
$50 |
 |
Knowledge Base  |
|
- 2-wire sensor cable.
- Use to connect dry contact sensors to the ENVIROMUX-SEMS-16.
- Available lengths (ft): 3/6/10/25/50/100
- Regulatory approvals: RoHS, UL
|
4-20mA Sensor Converter |
|

ENVIROMUX-S420MA $105  |
 |
|
- External RJ45 device monitors up to two 4-20mA analog sensors
- Supports ISA Type 2, ISA Type 3, and ISA Type 4 sensors
- Provides 18VDC, 25mA for each sensor
- Connector: Screw Terminal, 8-position.
- Supports CAT5/5e/6 cable up to 1,000 ft. (not included)
- Includes Mounting Hardware
- Regulatory approvals: RoHS.