Server Environment Monitoring System - ENVIROMUX-REMS-CLR
zoom-in on imageClick here to zoom in on image

ENVIROMUX-REMS-CLR (Front & Back)
Monitors Threats:
· High Temperature
· Low Humidity
· Intrusion
· Water Leakage
· Vibration


Discontinued. No longer available.

Features & Applications

The Server Environment Monitoring System monitors critical environmental conditions, such as temperature, humidity, water, motion, intrusion, and vibration. When a sensor exceeds a configurable threshold, the system will notify you via email, LED, buzzer, LCD, and network management (SNMP).
  • Monitor and manage server room environmental and security conditions over IP.
  • Create alarm signals with customized input parameters.
  • Internal power supply for all sensors.
    • Access Authorization System requires an external power supply (included).
  • Operates and configures via SNMP, HTTP, TELNET or V.24 terminals.
  • Supports SMTP protocol.
  • Alerts are sent using email and SNMP traps when any monitored environmental condition exceeds a user-specified range.
    • Alerts are posted in message log, which is accessible through RS232 and Web user interface.
    • Sends email notifications of alerts to a maximum of eight email addresses.
  • Generates syslog messages.
  • 1RU rack mount case is standard.

Specifications

Server Environment Monitoring System Specification Drawing
1. Power Port
  • 110 or 230 VAC at 50 or 60 Hz via IEC connector.
  • Connection for Earth Ground.
  • Fuse protection.
2. AC Voltage Monitoring Connections
  • Three screw terminal pairs for connecting three AC voltages.
  • Potential-free, no common ground reference.
  • Input voltage: 50-255 VAC.
3. Digital Outputs
  • Four screw terminal pairs.
  • Potential-free relay switch contacts.
  • Maximum switching load: 1.5 A at 230 VAC, 2 A at 30 V DC.
  • Individually fuse protected.
4. Digital Inputs
  • Eight screw terminal groups (of four terminals) for connecting dry contact devices.
  • Potential-free.
  • Input voltage: +5 V DC to +25 V DC.
  • With auxiliary +12 V DC supply, maximum current draw of 200 mA.
  • Fuse protection.
5. Alert Inputs
  • Four screw terminal pairs for connecting four signals or dry contact devices.
  • Maximum drawable alarm current approximately 20 mA.
6. Digital Inputs Temperature/Humidity
  • Four RJ22 modular jacks for connecting temperature sensors, humidity sensors and/or combined temperature/humidity sensors.
7. UPS Input
  • Two screw terminal pairs for connecting UPS switching outputs.
  • Input voltage: +5 V DC to +25 V DC.
8. Ethernet Port
  • One 10 Base-T Ethernet port with RJ45 Ethernet connector.
9. AUX Port
  • One male DB9 RS232 serial port for controlling and monitoring external equipment, such as the Access Authorization System or an air conditioner.
10. COM Port
  • One male DB9 RS232 serial port for terminal access.

Sensors - Sold Separately

Protocols
  • Telnet, HTTP, SNMP, SMTP
Dimensions
  • WxDxH (in.): 19x9.1x1.75
  • Weight: 8.5 lbs.
Regulatory Approvals
  • CE
Environmental
  • Operating temperature: 41°F to 104°F (5°C to 40°C).
  • Operating and Storage Relative Humidity: 5 to 85% non-condensing RH.
Warranty
  • Six months

Application Drawing - ENVIROMUX-REMS

Control Methods

  • Configuration can be done using the front panel interface, through direct connection to the serial port (RS232), or over the Internet/LAN via Web page or Telnet.
Front Panel Interface
  • Use front panel buttons to move through LCD screens and execute actions.
  • LEDs indicate the following:
    • "Fault" (red) lights up in connection with Reset, Overload or a serious system fault.
    • "Warning" (yellow) lights up if a sensor exceeds a configurable threshold, when booting and in connection with Reset.
    • "Power" (green) lights up when the device is supplied with voltage.
  • One RJ22 communication socket for connection to a PC or terminal (male RJ22 to female 9-pin RS232 serial communication cable included).
RS232 Control
  • Serial baud rate: 9600bps.
  • Data format: 8 data bits without parity, 1 stop bit.
  • Software handshake.
Telnet
  • Simple parameter configuration and evaluation of equipment data using Telnet.
  • Security is ensured by password.
Web Interface
  • Set thresholds for warning and alarm conditions.
  • View sensor status.
  • View message log.
  • Up to 99 users can access the web page at one time.
Administrative Controls
  • "Read-Only" or "Read/Write" privileges can be assigned to each user.
    • "Read-Only" users cannot save changes or access administration functions.
  • View and/or modify user passwords and parameters.
  • Change/disconnect users, administrators, passwords, etc.
  • A maximum of 99 users can be created.
Network Configuration
  • When the system is integrated into a local network, the following functions are available:
    • SNMP support, allowing integration into network management platforms.
    • Log book functional capabilities (syslog service).
    • Loading and saving the system configuration (TFTP).
    • Updating the system (TFTP).