Environment Monitoring System Motion Detection Sensors
Motion/Intrusion Sensors compatible with ENVIROMUX® E-2D, -5D and E-16D
Motion Detector Sensors
Low-Cost Infrared Motion Sensor
E-IMD-LCV2
Registers movement in area covered: 39x39 ft (12x12 m), 110° wide.
Condition display via LED.
Intelligent logic control prevents false alarms.
Wall mount or hang in a corner.
Good RFI protection.
Screw terminal.
Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Current consumption: 20mA @ 12VDC.
Powered by the E-2D/5D/16D.
Operating temperature: 14 to 122°F (-10 to 50°C)
Includes mounting bracket for installing the sensor to a ceiling or wall.
Outdoor weatherproof - high reliability against water and insects
Double conductive shielding to eliminate false alarms from light sources
Registers movement in the area covered: 40 ft (12 m) x 50 ft (15 m) - 120° wide
LED lights during detection
Selectable detection paterns: Multi-Level (40 zones) or Pet Alley (18 zones)
Unwanted detection areas can be eliminated using the included area masking strips
Selectable Sensitivity: High, Mid and Low
Adjustable to the brightness of surrounding environment with the Day/Night Mode switch
Tamper switch opens when cover is removed
Screw terminal.
Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Operating temperature: -4 to 122°F (-20 to 50°C)
IP54 compliant
Current consumption: 25mA @ 12VDC.
Powered by E-2D/5D/16D.
High-Mount Outdoor Infrared Motion Sensor
E-IMD-OHM
High-mount outdoor weatherproof sensor with 94 detection zones.
Unique pyro-element provides multiple pattern detection and accurate discrimination function for spot temperature changes of moving objects.
Drastically reduces false and missed alarms caused by severe outdoor environmental changes.
Upper and lower area must be activated to generate an alarm condition.
Summer night compensation, advanced temperature compensation, and vegetation sway analysis logic.
Ideal detection area setting – adjustable length/spot detection.
Registers movement in area covered: 13/18/30/40 ft and 85° wide.
LED indicators for operation and system status.
Unwanted detection areas can be eliminated using the included area masking seal.
Mounting height: 8.3 to 10 feet.
Tamper switch opens when cover is removed.
Screw terminal.
Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Registers movement in area covered: 36 ft (11 m) diameter, 12 ft (3.6 m) from ceiling.
Provides substantial immunity to false alarms caused by environmental disturbances.
Pulse count or single shot triggering.
Good RFI protection
Screw terminal.
Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Single-beam infrared motion sensor sends alert signal when invisible beam is broken.
Sensing range: up to 50 feet (15m)
Four selectable frequencies to reduce interference.
Light Source: Infrared LED, wavelength 940nm
LED Beam Spread Angle: Approximately ±10°
Built-in AGC control to filter out lighting disturbances.
LED indicator for power, signal strength, and alarm.
NO/NC relay (set by jumper, default is N.C.)
Screw terminal.
Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Operating temperature: -13 to 131°F (-25 to 55°C).
Dual Photobeam Detector, Indoor to 790', Outdoor to 390'
E-PBD-DOxxx
Twin infrared beams provide reliable perimeter security, minimizing false alarms from falling leaves, birds, etc.
Lensed optics reinforce beam strength and provide excellent immunity to false alarms due to rain, snow, mist, etc.
Sensing range:
E-PBD-DO90: indoor to 190', outdoor to 90'
E-PBD-DO190: indoor to 390', outdoor to 190'
E-PBD-DO290: indoor to 590', outdoor to 290'
E-PBD-DO390: indoor to 790', outdoor to 390'
Four selectable beam frequencies.
Laser wavelength: 650nm
LED indicator for power, signal strength, and alarm.
NC/NO alarm output.
Screw terminal.
Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Operating temperature: -13 to 131°F (-25 to 55°C).
Dimensions WxDxH (in): 2.9x6.8x2.8 (74x173x72 mm)
Max current (Tx and Rx):
E-PBD-DO90: 64mA
E-PBD-DO190: 70mA
E-PBD-DO290: 74mA
E-PBD-DO390: 88mA
Powered by the E-2D/5D/16D.
Includes mounting hardware.
Weatherproof, sunlight-filtering case for indoor and outdoor use.
Anti-frost system so that beam functions even in extreme conditions.