Environment Monitoring System Door Contact Sensors & Contact Switches
Door Contact Sensors compatible with ENVIROMUX® E-2D, E-5D and E-16D
Door Contact Sensors
Door Contact Sensor
E-M-DCS3
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary).
Can also be used for monitoring side wall and covers.
Includes mounting hardware.
For normally closed circuit connection.
Screw terminal.
Connect to digital input or RJ45 sensor port on an E-2D/5D/16D.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary).
Can also be used for monitoring side wall and covers.
Includes mounting hardware.
For normally closed circuit connection.
Screw terminal.
Connect to digital input or RJ45 sensor port on an E-2D/5D/16D.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Actuating gap: up to 1 inch (25 mm).
Dimensions WxDxH (in):
Switch: 0.34x0.38x2.00 in (9x10x51 mm).
Magnet: 0.34x0.38x2.00 in (9x10x51 mm).
Life cycle: 10,000,000 cycles
Operating temperature: -67 to 158°F (-55 to 70°C).
Use to monitor access from sliding doors and windows.
A captive magnet within the plunger activates a reed switch when the plunger is depressed.
Plunger travel: 0.25" (6mm)
Includes mounting hardware.
For normally closed circuit connection.
Screw terminal.
Connect to digital input or RJ45 sensor port on an E-2D/5D/16D system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Maximum cable length: 1,000 ft
Dimensions: 1.00x1.41x1.75
Operating temperature: -13 to 158°F (-25v to 70°C)
Rugged Door Contact Sensor with Universal-Style Magnet
E-DCSR-U
Monitors access with a magnetic bridge sensor (no special inserts necessary).
Ideal for commercial and industrial installations in harsh environments.
Heavy-cast metal housing with 3.06-feet armored cable.
Floor-mounting hardware included.
niversal-style magnet option has a smaller width and depth that provides greater installation flexibility.
For normally open or normally closed circuit connected.
Wide actuating gap up to 2.5 inches (63 mm).
Screw terminal.
Connect to digital input or RJ45 sensor port on an ENVIROMUX system.
To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.