Environment Monitoring System Smoke Detectors

Smoke Detection Sensors compatible with ENVIROMUX® E-1W

Smoke Detection Sensors

Low-Cost Smoke Detection Sensor – CE Approved

E-SDS-CELCP-V2 Low-Cost Smoke Detection Sensor – CE Approved
E-SDS-CELCP-V2
  • For warning of smoke.
  • Photoelectric smoke detector.
  • Smoke sensitivity: 0.5 dB/m ±0.1 dB/m.
  • Selectable latching feature.
    • Configure the sensor to auto-reset after an alarm trigger, or require a power cycle to unlatch the trigger.
  • Features a metal dust deterrent filter – dust/debris accumulates on the surface of the filter, leaving the mesh openings clear for smoke to travel through.
  • Compatible with E-1W.
    • Interfaces with the E-1W via the digital input sensor ports.
  • Screw terminal:
    • To connect to the digital inputs use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
  • Operating temperature: 14 to 122°F (-10 to 50°C).
  • Maximum cable length: 1,000 ft (305 m).
  • Includes 12V/1A power supply.
  • Regulatory approvals: CE, RoHS.
Downloads & References
NTI Part # Price Quote Buy
E-SDS-CELCP-V2 $50.00

Smoke Detection Sensor – 120VAC Wire-In with Battery Backup

E-SDS-120V Smoke Detection Sensor - 120VAC Wire-In with Battery Backup
E-SDS-120V
  • Self-Adhesive Clips for Liquid/Chemical Sensor Rope
  • For warning of smoke and invisible fire particles.
  • Ionization smoke detector.
  • Applications from 40°F to 100°F (4°C to 38°C).
  • Front loading battery door.
    • 9V battery backup (included) in case of power failure.
    • Battery run down protection.
  • One button design for easy testing and HUSH mode activation control.
    • LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode.
    • Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours.
  • Voltage supply: 120VAC.
    • Pre-stripped wiring harness with tinned strands
  • Audio alarm: 85dB at 10ft.
  • Dimensions: 5" diameter x 1.75" depth.
  • Dust cover prevents false alarms.
  • Tamper resist feature.
  • Links with up to 24 devices.
    • Max distance between first and last device: 1000ft (305m).
  • Alarm memory indicates initiating alarm in interconnected systems.
  • Use compatible relay (E-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting.
    • E-RLY-SDS120V includes normally open and normally closed contacts.
    • Contact ratings: 10A at 120VAC, 5A at 30VDC.
  • Compatible with E-1W.
  • Regulatory approvals: UL.
  • Compatible with the E-DI2-1W Digital Input Expander.
Downloads & References

NTI Part # Description Price Quote Buy
E-SDS-120V Smoke Detection Sensor - 120V $34.00
E-RLY-SDS120V Smoke Alarm Relay Module Compatible with E-SDS-120V $27.00

Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor – UL Approved

Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor – UL Approved
E-SDS-PA
  • For warning of smoke.
  • Photoelectric smoke detector.
  • Smoke sensitivity: 0.98-2.4%/ft.
  • Built-in 135°F (57°C) thermal heat sensor.
  • Includes mounting hardware.
  • Connect to digital input sensor ports.
  • Screw terminal
    • To connect to the digital inputs use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
  • Operating temperature: 14 to 122°F (-10 to 50°C).
  • Maximum cable length: 1,000 ft (305 m)
  • Includes 12V/1A power supply.
  • Compatible with E-1W.
  • Regulatory approvals: UL, RoHS
  • Compatible with the E-DI2-1W Digital Input Expander.
Downloads & References
NTI Part # Price Quote Buy
E-SDS-PA $82.00

Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor – UL Approved, TAA Compliant

Smoke Detection Sensor - UL Approved, TAA Compliant
E-SDS-TAA-PV2
  • For warning of smoke.
  • Photoelectric smoke detector.
  • Built-in 135° F (57° C) thermal heat sensor.
  • Connect to digital input sensor ports.
  • Voltage Supply: 8.5 to 35 VDC
  • Max Current Consumption:
    • 50uA max standby current @12VDC
    • 20mA max alarm current @12VDC
  • Alarm Output: Relay (NO)
  • Screw terminal
    • To connect to the digital inputs use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
  • Maximum cable length: 1,000 ft (305 m)
  • Includes 12V/1A power supply.
  • Compatible with E-1W.
  • Regulatory approvals: UL
  • TAA compliant
Downloads & References
NTI Part # Price Quote Buy
E-SDS-TAA-PV2 $145.00